Andonstar 246S User Manual Download Page 3

2

Safety and maintenance

1. Please read this users manual carefully before using the device. It may cause permanent damage to the
device to not follow the operation guide listed in this manual.
2. This product contains tiny parts and components that are NOT edible. Please let children and teens use
this device under proper guide and supervise by adults. Disables, patients and people with allergy should
not use this product.
3. We do not recommend using this product outdoor. It is not waterproof, and can not be placed in
extreme environment: heat, high pressure etc.. Please keep and use it in safe, clean and dry
environment. Stay it away from oil, gas, water and corrosive potions. Storage method refers to other
electronic products, such as a computer.
4. Clean the lens when image goes blurry: cut the power supply firstly, wipe the lens with a soft clean
cloth moistened with alcohol, make sure the whole device is dry before power it on again. Users should
follow these steps for daily cleaning as well, remember to ONLY wipe the INSULATED part of the
monitor.
5. The screen of the monitor is very fragile, please use it with care. Do not drop, hard press or leave it
with sharp object. Hold the frame of the monitor to adjust its orientation. The monitor is not waterproof,
please clean it with soft and dry material.
6. Please be aware that this microscope is not for medical use.

Specifications

Video resolution

UHD 2880x2160 24fps; FHD 1920x1080 60fps/30fps ;
HD 1280x720 120fps

Video Format

MP4

Frame rate

Max 120fps (600 Lus illumination &HDP120)

Magnification ratio Lens A: 18-720x; Lens D: 1800-2040x; Lens L: 60-240x

(with3 times digital zoom, output to 28inch HDMI monitor)

Working Distance

Lens A: 12mm-320mm; Lens D: 4mm- 5mm; Lens L: 90mm-300mm

Photo resolution

Max 5600*4200 (24M 5600*4200)

Photo Format

JPG

Storage

Micro-SD card, up to 32G (not included)

Video-output

HDMI

PC Support

Windows XP/7/8/10, PC software with measurement (gift)

Power supply

5V 2A and above

Stand size

20cm*18cm*33cm

Package include

Microscope, Metal stand, 3 Lenses(A,D&L), Slide holder, Remote,
Dimmer cable, HDMI cable, USB cable, Slides kit, Tweezers, Bug box

Summary of Contents for 246S

Page 1: ...Digital Microscope 246S 249S Users Manual metal stand...

Page 2: ...e 3 Video demonstration 3 Button Connection 4 Bracket installation 5 Bracket instructions 5 Quick Start 6 How to choose lens 7 Digital zoom 10 Save files to micro SD card 10 Remote 11 Settings 12 Outp...

Page 3: ...low these steps for daily cleaning as well remember to ONLY wipe the INSULATED part of the monitor 5 The screen of the monitor is very fragile please use it with care Do not drop hard press or leave i...

Page 4: ...le HDMI cable USB cable Slide holder Slides kit Tweezers Bug box P1 Package include Video demonstration Please find the video demo from the link Please type all letters properly capitalized QR code be...

Page 5: ...ower on off Mode Menu Up Digital zoom in Down Digital zoom out OK Start recording Take pictures while the device is recording Remote signal receiver where you aim remote to Focusing tube Lens fixing s...

Page 6: ...ram Bracket instructions P3 Bracket instructions Secondary Bracket Lift Boom Arm Lower Limit Stop Monitor Fixing Screws Spot Lights Clips Boom Arm V locker lock the arm in vertical direction Boom Arm...

Page 7: ...and its totally normal Trouble shooting When the monitor image stops or freezes please pin the Reset hole pic 2 to reset the device first then power on the device again Reset hole is very tiny located...

Page 8: ...tom of the focusing tube Bend the two goose neck spot lights make the field of view enough illuminated Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to...

Page 9: ...on the coin Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to the specimen should be around 12mm to 320mm then fix the V locker In order to adjust objec...

Page 10: ...lides holder Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to the specimen should be around 4mm to 5mm then fix the V locker Since the focus range is v...

Page 11: ...tton to select choose Format and confirm 5 Do not insert a card while microscope is working If you do the microscope would switch off automatically And you will have to turn it on again In order to ta...

Page 12: ...eeze Stop the image on the display works in video mode photo mode and while recording Illumination exposure compensation from 2 0 to 2 0 Sharpness up down three levels of sharpness Soft Normal Strong...

Page 13: ...ow And then press M again to get into settings menu as right below pic 9 video menu pic 10 setting menu Gridline Settings remote needed Use Up and Down to choose among Cross Line Line Direction Locati...

Page 14: ...see the following pic Pic 13 Delete line 1 before after Date Time Setting Select Date Time in setting menu press OK button to get in time setting Use up and down button to select correct number OK to...

Page 15: ...ownload the software https bit ly 3xCRDPL Currently software Microscope Measure only supports Windows system System requires Windows XP SP3 Windows 7 Windows8 Windows10 Runtime Microsoft Net Framework...

Page 16: ...Measure an ellipse Long axis radius short axis radius circumference area 3 points circle radius circumference area Measure a radius circle radius circumference area Edge detection Measure a diameter c...

Page 17: ...p of this window the result of measuring can be much more precisely Main operating window This windows shows the full view from the microscope And it is also the place where users do measuring and ima...

Page 18: ...istance for the rest steps 2 In the Calibration management set the name and unit length of the new calibration refer the picture on the right Then click Calibration meanwhile the in the toolbar should...

Page 19: ...roper place around the target 3 Special Effect Includes Edge detection Inverse color Flip horizontal Relief Sharpen and Smooth Steps 1 Choose the special effect you need in the toolbar 2 Move your cur...

Page 20: ...software can not recognize the microscope Firstly please make sure that you have connected the microscope to the PC properly and have chosen USB camera on the microscope monitor Secondly if there is...

Page 21: ...hows card error or card is full after inserting memory card to the device Please format the card after insert it into the device Format steps refer to chapter Save files to micro SD card PS If there a...

Reviews: