User Manual
3
be equipped with a suitable high pressure safety relief device, if the pipeline system is
equipped with a booster pump. When the inlet and outlet valves of cryogenic liquid storage
tank are both closed, nevertheless the rest of the fluid is still in this system, the import and
export of return pipeline in system also must be equipped with low pressure safety relief
device, which is called safety valve. If allow to heat cryogenic liquid in system, that will come
into being enough high pressure, which will result in nearly all vessel breaks and explosion,
along with which to release stored energy.
8. EXPLOSION-PROOF INSTRUCTIONS
1) Our pump applies to explosive gas atmospheres.
2) Only professional training personnel can inspect and repair the pump.
3) Should follow relevant order, resolution, law, directives and standards, which are
appropriate for this equipment installation.
4) The install stools used should apply to explosive gas atmospheres.
5) All of the safety accessories should be correctly installed, connected and set with
signal value.
9. USER RESPONSIBILITY
Installation, operation and maintenance of this equipment, which customer had ordered, must
follow the rules according to the manual and relevant document. Equipment with any defect
shall not be used anymore. Replaced the part immediately, once it has damage or wear or
deformation or contaminated. When need to repair or replace this equipment, contact the
franchiser.
If equipment failure or bad consequences result from user damage either because of
improper operation or maintenance, or use other company’s part, that shall be assumed by
customer.
10. SPARE/SERVICE
User can confirm the required spare parts from the Parts list (refer to the appendix) or the
corresponding assembly drawing. When user plan to order part, please provide the following
information:
1) Serial number of the product’s nameplate.
2) The name on the Parts list.
3) The required amount.
Company info.
Licensor: TRUFLOW CANADA INC.
Headquarters Address: 505- 2950 Glen Dr.
Coquitlam, BC, Canada
V3B 0G2