ANDILOG CENTOR FIRST II User Manual Download Page 9

 

User's manual 

CENTOR FIRST II 

 

- 9 - 

Battery indicator: 

varies between 0% and 100% to indicate the battery life. When the battery is new, 

the autonomy is about 15 hours in continuous use. When the battery percentage reaches 0% the force 

gauge turns off. 

 
Capacity display

: indicates the capacity of the sensor installed in the instrument. 

 

Bar graph: 

The bar graph shows the operator how much force is being applied relative to the 

maximum capacity of the load cell. When a compression force is applied, the bar graph fills up. When 
a tensile force is applied, the bar graph fills in downwards.  

Measurement display : 

 
A force applied in tension will be preceded by the symbol 

    

A force applied in compression will be preceded by the symbol 

  

 

 

 

 

The display order can be changed by pressing the 

 

  

3.3.1.

 

Do the Zero  

During tests, it is often necessary to reset the display to zero (e.g. to tare an accessory). Press the 

green 0

 key.  The display then shows 0. 

3.3.2.

 

Change the unit of measurement  

You can choose from the following units: N, kg, lb and daN. To change the unit display, press the 

U

 

key. Each successive press will select the next unit until you return to the starting unit. The Centor 
First II will automatically convert the display and capacity to the new chosen unit and display the 
corresponding unit symbol. 

Indicates the direction of the 
measurement (tension or 
compression). Force measured 
in instantaneous 
Maximum traction from the 
tare 

Maximum compression from 
tare 

Summary of Contents for CENTOR FIRST II

Page 1: ...s manual CENTOR FIRST II User s manual CENTOR FIRST II ANDILOG Technologies BP62001 13845 Vitrolles Cedex France COM TEN Industries 6405 49th Street North Pinellas Park FL 33781 USA Site www andilog...

Page 2: ...4 2 Getting started 6 2 1 Battery charging 6 2 2 Mounting the Accessories 6 2 3 Mounting on a frame 6 3 Using the CENTOR FIRST 7 3 1 Starting up 7 3 2 Extinguishing 8 3 3 Measurement screen 8 3 3 1 D...

Page 3: ...h a battery charge between 30 and 80 of its autonomy It is recommended to use the original power supply provided by Andilog to charge your instrument The power supply must have the following character...

Page 4: ...emperature 20 to 45 C Relative humidity 5 to 95 non condensing Maximum altitude of use 3 000 m 1 2 6 Warranty Subject to the conditions below Andilog Technologies warrants to the purchaser that it wil...

Page 5: ...entation or offers If products are damaged during shipment notify the carrier and Andilog Technologies immediately The warranty is void in case of accident misuse or abuse Calibrations overloaded sens...

Page 6: ...hould be done by hand without applying much torque Excessive torque or the use of pliers can damage the load cell We recommend that you mount the accessories with the force gauge turned on to ensure t...

Page 7: ...evice is functional the force gauge displays the measurement screen It then displays 0 N A tare is performed when the device is started If the applied force is greater than 20 of the maximum capacity...

Page 8: ...n the force gauge is turned off The force gauge will operate with the same settings when it is turned back on unit display order 3 2 Extinguishing To turn off the Centor First II press and hold the bu...

Page 9: ...on will be preceded by the symbol A force applied in compression will be preceded by the symbol The display order can be changed by pressing the 3 3 1 Do the Zero During tests it is often necessary to...

Page 10: ...display The Centor First II remembers the display order when it is turned off 3 3 4 Auto off The automatic shutdown saves the battery charge The force gauge is automatically switched off after 15 min...

Page 11: ...using the on off key My device does not display the measurement screen but an information page with Offset in red If the offset value is greater than 20 the device cannot measure Turn off your device...

Page 12: ...User s manual CENTOR FIRST II 12 Characteristic Capacity Accuracy 0 25 of capacity Autonomy 3 p m Power supply MicroUSB 5V 1A Net weight 520 g Units N daN kg lb Sensor sampling frequency 1000 Hz...

Reviews: