P
AGE
7
FIGURE 5-1 Standard Termination Details (for all applications except CE)
SHRINK WRAP OR TAPE
OUTER CABLE
JACKET
INNER FOIL WRAP
CELLOPHANE WRAP
OUTER FOIL WRAP
3 INCHES
(76 mm)
1/8 INCH
(3 mm)
COMBINED SHIELD
(SHRINK WRAPPED OR TAPED)
CABLE SHIELD WIRE
SIGNAL SHIELD WIRE
5.2 STANDARD TERMINATION PROCEDURE (FOR ALL APPLICATIONS EXCEPT CE)
5.2 STANDARD TERMINATION PROCEDURE (FOR ALL APPLICATIONS EXCEPT CE)
5.2 STANDARD TERMINATION PROCEDURE (FOR ALL APPLICATIONS EXCEPT CE)
5.2 STANDARD TERMINATION PROCEDURE (FOR ALL APPLICATIONS EXCEPT CE)
5.2 STANDARD TERMINATION PROCEDURE (FOR ALL APPLICATIONS EXCEPT CE)
CAUTION:
USE THIS STANDARD TERMINATION PROCEDURE TO TERMINATE THE
SENSOR OR INTERCONNECT CABLE UNLESS THE MEASURING
INSTRUMENT HAS THE EUROPEAN COMMUNITY "CE" LABEL. IN THIS
CASE, USE THE CE TERMINATION PROCEDURE DESCRIBED IN SECTION
5.3.
1.
Refer to Figure 5-1 and strip back 3 inches (76 mm) of the outer cable jacket, outer foil
wrap, cellophane wrap, inner foil wrap, and unused black wire. This exposes the signal
shield wire, the cable shield wire, and five colored wire (red, green, yellow, white, and
blue).
2.
Twist the signal shield wire and cable shield wire together, and insulate the new
combined shield wire with shrink wrap or tape.
3.
Strip the insulation back 1/8 inch (3 mm) from each of the colored wires. Then tin each
stripped wire.
4.
Using shrink wrap or tape, secure the terminated bundle (outer cable jacket, five
colored wires and combined shield wire). This completes the standard termination.