background image

P

AGE

  11

Section 8 - W

Section 8 - W

Section 8 - W

Section 8 - W

Section 8 - Warranty and R

arranty and R

arranty and R

arranty and R

arranty and Return Statement

eturn Statement

eturn Statement

eturn Statement

eturn Statement

These products are sold by The Anderson Instrument Company  (Anderson) under the

warranties set forth in the following paragraphs.  Such warranties are extended only with

respect to a purchase of these products, as new merchandise, directly from Anderson or from

an Anderson distributor, representative or reseller, and are extended only to the first buyer

thereof who purchases them other than for the purpose of resale.

Warranty

These products are warranted to be free from functional defects in materials and workmanship

at the time the products leave the Anderson factory and to conform at that time to the

specifications set forth in the relevant Anderson instruction manual or manuals, sheet or sheets,

for such products for a period of one year.

THERE ARE NO EXPRESSED OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE
WARRANTIES HEREIN AND ABOVE SET FORTH.  ANDERSON MAKES NO WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO
THE PRODUCTS.

Limitations

Anderson shall not be liable for any incidental damages, consequential damages, special

damages, or any other damages, costs or expenses excepting only the cost or expense of

repair or replacement as described above.

Products must be installed and maintained in accordance with Anderson instructions.  Users

are responsible for the suitability of the products to their application.  There is no warranty

against damage resulting from corrosion, misapplication, improper specifications or other

operating condition beyond our control.  Claims against carriers for damage in transit must be

filed by the buyer.

This warranty is void if the purchaser uses non-factory approved replacement parts and

supplies or if the purchaser attempts to repair the product themselves or through a third party

without Anderson  authorization.

Returns

Anderson’s sole and exclusive obligation and buyer’s sole and exclusive remedy under the

above warranty is limited to repairing or replacing (at Anderson’s option), free of charge, the

products which are reported in writing to Anderson at its main office indicated below.

Anderson is to be advised of return requests during normal business hours and such returns

are to include a statement of the observed deficiency.  The buyer shall pre-pay shipping

charges for products returned and Anderson or its representative shall pay for the return of the

products to the buyer.

Approved returns should be sent to:

ANDERSON INSTRUMENT COMPANY INC.

156 AURIESVILLE ROAD

FULTONVILLE, NY 12072  USA

ATT: REPAIR DEPARTMENT

Summary of Contents for HC1 Series

Page 1: ..._______________________ Instrument Serial Number ____________________________ Form Number AIC2032 June 2003 Rev 2 13 Model HC1 Series Model HC1 Series Model HC1 Series Model HC1 Series Model HC1 Series Electrodless Conductivity Sensors Electrodless Conductivity Sensors Electrodless Conductivity Sensors Electrodless Conductivity Sensors Electrodless Conductivity Sensors ...

Page 2: ... STANDARD TERMINATION PROCEDURE EXCEPT CE 8 5 3 STANDARD TERMINATION PROCEDURE EXCEPT CE 8 5 4 INTERCONNECT CABLE DETAILS 9 5 4 INTERCONNECT CABLE DETAILS 9 5 4 INTERCONNECT CABLE DETAILS 9 5 4 INTERCONNECT CABLE DETAILS 9 5 4 INTERCONNECT CABLE DETAILS 9 Section 6 T Section 6 T Section 6 T Section 6 T Section 6 Troubleshooting roubleshooting roubleshooting roubleshooting roubleshooting 10 10 10 1...

Page 3: ...ications Section 2 Specifications Wetted Materials PVDF or PFA Teflon Operating Temperature Range 14 to 347 F 10 to 175 C Measuring Range From 0 200 to 0 2 000 000 microSiemens cm Temperature Compensator Pt 1000 RTD Sensor Cable 5 conductor plus two isolated shields cable with Teflon coated jacket rated to 175 C 347 F 20 ft 6 m long Pressure Temperature Limits 200 psi at 347 F 13 8 bar at 175 C Ra...

Page 4: ... junction box that has a terminal strip onto a flat surface Make sure the junction box cover can be removed after installation 3 Before installing the sensor into the process line or vessel calibrate the measuring system with conductivity reference solution using the procedure in the instrument operating manual 4 After calibration mount the sensor into the sanitary tee or ferrule A Properly seat t...

Page 5: ...PAGE 5 FIGURE 4 1 Sanitary Mounting Details 2 67 8 54 1 91 2 67 9 08 1 91 ...

Page 6: ...tions except those using instruments with the European Community CE label The sensor cable is terminated with five colored wires red green yellow white and blue and one shield wire signal shield wire and cable shield wire are electrically common CE Termination Available by special order for applications using instruments with the European Community CE label The sensor cable is terminated with five...

Page 7: ...OCEDURE TO TERMINATE THE SENSOR OR INTERCONNECT CABLE UNLESS THE MEASURING INSTRUMENT HAS THE EUROPEAN COMMUNITY CE LABEL IN THIS CASE USE THE CE TERMINATION PROCEDURE DESCRIBED IN SECTION 5 3 1 Refer to Figure 5 1 and strip back 3 inches 76 mm of the outer cable jacket outer foil wrap cellophane wrap inner foil wrap and unused black wire This exposes the signal shield wire the cable shield wire a...

Page 8: ...il wrap This exposes the signal shield wire cable shield wire and cellophane wrapped wire bundle 2 Fold back the cable shield wire Using shrink wrap or tape equally cover the outer cable jacket and the exposed cable shield wire cellophane wrapped wire bundle 3 Carefully clip back the cellophane wrap inner foil wrap and unused black wire up to the end of the shrink wrap or tape applied in step 2 Th...

Page 9: ...pecific cable characteristics protect the measurement signal from electromagnetic interference Using a cable with different construction may interfere with the measuring system s ability to operate properly If the application requires interconnect beyond the standard 20 length the use of a Interconnect Cable Junction box is required to ensure a quality connection 1 Mount the junction box on a flat...

Page 10: ...an 5 ohms 5 Place the ohmmeter to its highest range and measure the resistance between the shield and white wires The reading should indicate infinity open circuit If any one of the resistance checks in the previous steps is incorrect the sensor is probably defective Contact Anderson Instrument Company for details on arrang ing a sensor replacement If the resistance checks are correct the sensor m...

Page 11: ...ntial damages special damages or any other damages costs or expenses excepting only the cost or expense of repair or replacement as described above Products must be installed and maintained in accordance with Anderson instructions Users are responsible for the suitability of the products to their application There is no warranty against damage resulting from corrosion misapplication improper speci...

Reviews: