Order designation

MPI-200 

Programming adapter for setting parameters of Anderson-Negele 2-wire sensors, incl. PC software

MPI-200

Product Information MPI-200

Information on the installed software version

Click on “Help > Info” in the main menu.

Cleaning/maintenance

 ·

In case of using pressure washers, dont‘t point nozzle 

directly to electrical connections!

Reshipment

 ·

Sensors and process connection must be clean and must 

not be contaminated with hazardous media and/or heat-

conductive paste. Note the cleaning information!

 ·

To avoid damage of the equipment, use suitable trans-

port packaging only.

Transport/storage 

 ·

Do not store outside

 ·

Store in an area that is dry and dust-free

 ·

Do not expose to corrosive media

 ·

Protect against solar radiation

 ·

Avoid mechanical shock and vibration

 ·

Storage temperature -40...+85 °C

 ·

Relative humidity maximum 98%

Standards and guidelines

 ·

Compliance with the applicable regulations and 

 

directives is mandatory.

Notice on conformity

Applicable guidelines: 

 

·

Electromagnetic Compatibility Directive 2004/108/EC

 

·

The CE label confirms compliance of this product with 

the applicable EC directives.

 

·

You have to guarantee the compliance of all guidelines 

applicable for the entire equipement.

Disposal

 

·

This instrument is not subject to the WEEE directive 

2002/96/EC and the respective national laws.

 

·

Give the instrument directly to a specialized recycling 

company and do not use the municipal collecting points.

Summary of Contents for MPI-200

Page 1: ...her requirement CD drive for program installation Access rights Administrator rights for installation Installing the software 1 Insert the CD included with the MPI 200 into the CD drive 2 Double click...

Page 2: ...external M12 connected A supply from the PC would otherwise be superimposed on the 4 20 mA output signal and lead to an incorrect measur ing signal Electrical connection Power supply Connecting the se...

Page 3: ...t Reconnect Establishing a connection with a sensor reading in the parameter structure again manually Mode Mode setting Monitoring Process values and service information can be viewed but not changed...

Page 4: ...ed e g 4 mA for a mA setpoint Save parameter The manually created setting is adopted and the display returns to the main menu Discard parameter The setting is not adopted and the display returns to th...

Page 5: ...at can only be set to xed values By pressing the arrow buttons Only values that are greater than the cur rently displayed value are possible Only values less than the currently displayed value are pos...

Page 6: ...out and saved After the language and the printer are selected in the option field 3 the process can be completed by clicking the OK button 1 2 3 Export function of the parameter list After the print m...

Page 7: ...supply MPI 200 parameter set to PC Set the appropriate power supply Error message when the software is started Is NET 4 0 or higher installed on the PC Install NET from the supplied CD path NET4 0 Er...

Page 8: ...te Note the cleaning information To avoid damage of the equipment use suitable trans port packaging only Transport storage Do not store outside Store in an area that is dry and dust free Do not expose...

Reviews: