ANDERSON-NEGELE MPI-200 Product Information Download Page 3

C O N T R O L S

3

User interface

Maximum display

1:  Button bar

2:  Parameter structure

3:  Details on the individual settings 

or parameters, if activated 

(

 button)

Status bar 

4:  Operating time since start of 

software

5:  Power supply

6:  Mode

7:  MPI-200 connection to PC 

8:  Status

1.
2.

3.

5.

4.

6.

7.

8.

Maximum display | Buttons

Button bar: Button description and meaning

  

Parameter Data - Import Data File

   

Confi guration profi les of sensors can be loaded

  

Parameter Data - Export Data File

   

Confi guration profi les of sensors or their individual components can be saved

  

Parameter Data - Print

   

The parameter list of the connected sensor can be printed out

  

Reconnect!

   

Establishing a connection with a sensor/reading in the parameter structure again manually

  

Mode

   

Mode setting

 

Monitoring:

 Process values and service information can be viewed but not 

changed 

Adjustment: 

Access to the most frequently required parameters 

Setup

: Access to special parameters that are primarily needed during installa-

tion (defaults settings on delivery)  

Calibration

: Factory setting for calibration. Access to this menu is only possible 

on request

 

  

Help Text

   

Showing/hiding help texts 

Summary of Contents for MPI-200

Page 1: ...her requirement CD drive for program installation Access rights Administrator rights for installation Installing the software 1 Insert the CD included with the MPI 200 into the CD drive 2 Double click...

Page 2: ...external M12 connected A supply from the PC would otherwise be superimposed on the 4 20 mA output signal and lead to an incorrect measur ing signal Electrical connection Power supply Connecting the se...

Page 3: ...t Reconnect Establishing a connection with a sensor reading in the parameter structure again manually Mode Mode setting Monitoring Process values and service information can be viewed but not changed...

Page 4: ...ed e g 4 mA for a mA setpoint Save parameter The manually created setting is adopted and the display returns to the main menu Discard parameter The setting is not adopted and the display returns to th...

Page 5: ...at can only be set to xed values By pressing the arrow buttons Only values that are greater than the cur rently displayed value are possible Only values less than the currently displayed value are pos...

Page 6: ...out and saved After the language and the printer are selected in the option field 3 the process can be completed by clicking the OK button 1 2 3 Export function of the parameter list After the print m...

Page 7: ...supply MPI 200 parameter set to PC Set the appropriate power supply Error message when the software is started Is NET 4 0 or higher installed on the PC Install NET from the supplied CD path NET4 0 Er...

Page 8: ...te Note the cleaning information To avoid damage of the equipment use suitable trans port packaging only Transport storage Do not store outside Store in an area that is dry and dust free Do not expose...

Reviews: