Application/specifi ed usage

 

·

Universal programming of Anderson-Negele sensor in 2-wire technology

Scope of supply

 

·

Programming adapter MPI-200 

 

·

CD with PC software

System requirements

 

·

Operating system: WinXP (SP3 and higher), Vista (SP1 and higher), Win7 

 

·

Processor: min. 1 GHz CPU 

 

·

Available hard disk space: min. 10 MB (.NET is already installed) 

 

·

Windows installer: 3.1 

 

·

.NET version 4.0 

 

·

USB: 1 vacant USB interface USB 2.0 

 

·

Other requirement: CD drive for program installation 

 

·

Access rights: Administrator rights for installation

Installing the software 

1.  Insert the CD included with the MPI-200 into the CD drive 

2.  Double-click on the “Anderson-Negele Installer.msi” fi le to start the 

installation 

3.  Follow the instructions of the installation wizard 

4.  After the installation is fi nished, the following symbol appears on the 

desktop 

Product Information MPI-200

Programming adapter MPI-200

 MPI-200 user interface

Programming adapter MPI-200

1.

Changing the user interface language 

The software is factory-provided confi gured to English. It can be changed as 

follows: 

1.  Open the “

Language

” parameter 

2. 

 Press the button 

3.  Select the language using the arrow buttons 

4.  Save the setting by pressing the 

 button 

5.  The interface now refreshes in the new language

4. 2.

3.

Summary of Contents for MPI-200

Page 1: ...her requirement CD drive for program installation Access rights Administrator rights for installation Installing the software 1 Insert the CD included with the MPI 200 into the CD drive 2 Double click...

Page 2: ...external M12 connected A supply from the PC would otherwise be superimposed on the 4 20 mA output signal and lead to an incorrect measur ing signal Electrical connection Power supply Connecting the se...

Page 3: ...t Reconnect Establishing a connection with a sensor reading in the parameter structure again manually Mode Mode setting Monitoring Process values and service information can be viewed but not changed...

Page 4: ...ed e g 4 mA for a mA setpoint Save parameter The manually created setting is adopted and the display returns to the main menu Discard parameter The setting is not adopted and the display returns to th...

Page 5: ...at can only be set to xed values By pressing the arrow buttons Only values that are greater than the cur rently displayed value are possible Only values less than the currently displayed value are pos...

Page 6: ...out and saved After the language and the printer are selected in the option field 3 the process can be completed by clicking the OK button 1 2 3 Export function of the parameter list After the print m...

Page 7: ...supply MPI 200 parameter set to PC Set the appropriate power supply Error message when the software is started Is NET 4 0 or higher installed on the PC Install NET from the supplied CD path NET4 0 Er...

Page 8: ...te Note the cleaning information To avoid damage of the equipment use suitable trans port packaging only Transport storage Do not store outside Store in an area that is dry and dust free Do not expose...

Reviews: