Specification
Specification
Load Stand
®
II Weighing Cells
Technical Features
Excitation Voltage - Operating Range
Maximum Current
Recommended Supply Voltage
Functional Integrity
Humidity
Protection Class
Materials
Sensor
Junction Box
12...30 V DC Half-Bridge
15.52 mA @ 12 VDC excitation
12 V DC
2 x rated load (compression)
100 % Non-condensing
Designed for outdoor applications
Pedestal: Carbon Steel 1.0044
(ASTM A53 GR)
Flanges: Carbon Steel 1.0459
(ASTM A36)
Finish: Polyester Powder Coating
4 x Microcell II
Plastic or Stainless Steel (ATEX),
included
Measurement Accuracy
Non-Linearity/Hysteresis Combined
Repeatability
Rated Output
No Load Output
0.2 % of rated load
0.2 % of rated load
320 mV DC @ 12 V DC ±1 %
±50 mV
Temperature ranges
Ambient Temperature Range
Operational Temperature Range
Storage Temperature Range
Standard: -18...38 °C (0...100 °F)
Mid: 10...66 °C (50...150 °F)
-34...66 °C (-30...150 °F) (outside this
range the accuracy may be reduced)
-34...66 °C (-30...150 °F)
Authorizations
All models
ATEX (option)