background image

SRA

MS-70

MX-50

MF-50

ML-50

MS-70

MX-50

MF-50

ML-50

A

&

D's Moisture Analyzers

A

&

D's Moisture Analyzers

Fast and uniform heating with halogen lamp and innovative SRA technology

Straight halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter gives shorter 
measurement time, thanks to fast and uniform heating

High repeatability

With SHS (Super Hybrid Sensor) featured as the weight sensor, ultra accurate moisture content 
determination is possible based on high precision weighing of even a small sample

Low moisture content measurement

MS-70 measures the moisture content at 0.001% resolution suitable for low moisture content samples 
as well as Karl Fischer method, yet requires no special knowledge or training and produces no harmful waste

Standard WinCT-Moisture 

(for MS

&

MX)

 for real-time graph displaying

WinCT-Moisture is an original software application designed to display a graph of moisture content 
rate change while measuring with a connected PC

Sodium Tartrate Dihydrate comes as standard for accuracy checking

Sodium Tartrate Dihydrate is a chemical material that has stable moisture content of 15.66%     , 
and thus is best to use for accuracy check to maintain the reference value of the analyzer

Calibration of the heater temperature 

(for MS

&

MX)

With the temperature calibrator (optional), calibration result can be output in the format that 
conforms to GLP, GMP, ISO

Memory function

According to sample up to 20 suitable measurement conditions can be stored and recalled, which saves time 
and prevents the user from making a mistake when setting (10 for MF 

&

 5 for ML)

For measurement result, up to 100 data can be stored and output at once (50 for MF 

&

 30 for ML)

Five measurement programs

Five choices of measurement programs, Standard, Automatic, Quick, Timer, and Manual Mode are provided
Standard Mode : Just measurement accuracy, HI, MID or LO needs to be set
Automatic Mode : Ends measurement when moisture content changes at a rate less than the set rate
Quick Mode : Begins heating samples at 200

°

C for 3 minutes, then is the same as Automatic Mode

Timer Mode : Continues measurement for a set duration of time (1

˜

60mins.: by 1min, 60

˜

480mins.: by 5mins.)

Manual Mode : STOP button should be pressed to end measurement (Max. heating time: 480mins.)

Selectable Heating Mode

Choose the heating mode from standard, quick, step and ramp heating modes for the most suitable measurement 
(ML has Standard and Quick heating modes only)

Clear and easy-to-see, large VFD display

Measurement, setting value, change in moisture content, action status, data number and other important 
information are clearly displayed

Easy handling of the unit

Ergonomically designed pan handle eliminates mishaps such as burns when moving a hot sample pan into or 
out of the unit from either side. Wing handle for easy opening and closing of the heater cover

Low maintenance cost assured

The halogen lamp is user replaceable without unit downtime with protective chamber for easy cleaning
(Lamp life 5000 hours)

+0.3

–0.1

SHS

Summary of Contents for MF-50

Page 1: ...Moisture Analyzers ISO 9000 CERTIFIED http www aandd jp Moisture Analyzers MS 70 MX 50 MF 50 ML 50 MS 70 MX 50 MF 50 ML 50 ...

Page 2: ...mory function According to sample up to 20 suitable measurement conditions can be stored and recalled which saves time and prevents the user from making a mistake when setting 10 for MF 5 for ML For measurement result up to 100 data can be stored and output at once 50 for MF 30 for ML Five measurement programs Five choices of measurement programs Standard Automatic Quick Timer and Manual Mode are ...

Page 3: ...lled at the bottom of the analyzer Standard RS 232C Bi directional communication with a PC or connects directly to a printer Conformity to GLP GMP GCP and ISO with date time ID calibration data and check record outputs Data output for daily record management MS MX MF ML Select the best moisture analyzer for your application Test with The Best External Calibration Super Hybrid Sensor VFD Display RS...

Page 4: ...e measurement Patent pending Shows sample data summary Provides a data summary for the sample with the results of moisture rate change for the representative material s measurement Calculates measurement data statistics Saves the recorded data as a CSV file Determines other changes to the sample material in addition to moisture rate Continuously measures changes to the mass in response to heating ...

Page 5: ...S 70 and the KF Karl Fischer method Example of PET plastic pellet measurement Soybean flour Sodium tartrate dihydrate Corn starch Sodium tartrate dihydrate WinCT Moisture consists of RsTemp software to determine the heating temperature and RsFig software for graphics MS 70 KF method Moisture rate Average value 0 298 0 307 Repeatability standard deviation 0 0045 0 0065 Average measurement time 6 8 ...

Page 6: ...er 1g Standard Deviation over 5g Heating Technology Drying Temperature 1 C increment Memory of Measurement Programs Measurement Programs Measurement Mode Heating Mode Display Type Interface Data Memory Function Operating Temperature GLP GMP ISO Self Check Function Communication Software Sample Pan Size Power Physical Dimention Weight Standard Accessories 20 sets 100 WinCT Moisture standard 400W st...

Reviews: