background image

*

MS/ML-ADCC-12-PR7-11b03

Accessories

AD-8121B
AX-MX-30
AX-MX-31
AX-MX-32-1
AX-MX-32-2
AX-MX-33
AX-MX-34-120V
AX-MX-34-240V
AX-MX-35
AX-MX-36
AX-MX-37
AX-MX-38
AX-MX-39
AX-MX-40
AX-MX-41
AX-MX-42
AX-MX-43
AX-USB-25P

Dot Matrix Compact Printer
Disposable Aluminum Pan (100pcs)
Sample Pan (ø85mm x 100pcs)
Glass Fiber sheet (ø70mm x 100 sheets)
Glass Fiber sheet (ø78mm x 100 sheets)
Test Sample (Sodium Tartrate Dihydrate, 30g x 12pcs)
Halogen Lamp for AC100V to 120V
Halogen Lamp for AC200V to 240V
Pan Handle (2pcs)
Tweezers (2pcs)
Spoon (2pcs)
Display Cover (5pcs)
Dust Cover
RS-232C Cable (2m, 25-9pins)
Calibration Mass (20g, equivalent to OIML class F1)
WinCT-Moisture (CD-ROM, Application Software for Windows)
Certified Temperature Calibrator (only for MS/MX)
Serial/USB Converter

AD-8121B 

Dot Matrix Compact Printer

MS-70

71g

0.0001g

0.001%/0.01%/0.1%

0.05%

0.01%

30-200

°

C

Sample Pans (20 for MS/MX/MF 10 for ML), Pan Handles (2 for MS/MX/MF, 1 for ML), 
Tweezers(for MS/MX/MF), Spoon (for MS/MX/MF), Test Sample (30g of Sodium Tartrate 
Dihydrate for MS/MX/MF), CD-ROM (WinCT-Moisture for MS/MX, WinCT for MF), 
Glass Fiber Sheet (for MS/MX/MF), RS-232C Cable (for MS/MX), Display Cover, 
Dust Cover(for MS/MX/MF), Instruction Manual, Quick Reference Card, Power Cable, Fuse

ML-50

0.005g

0.1%/1%

0.5%

0.1%

5 sets

Standard/Quick

30

MF-50

51g

0.002g

0.05%/0.1%/1%

0.20%

0.05%

50-200

°

C

10 sets

50

WinCT standard

MX-50

0.001g

0.01%/0.1%

0.10%

0.02%

Standard/Quick/Step/Ramp

Specifications

Specifications are subject to change for improvement without notice.   

Measurement Method 

Max Sample Weight Capacity  

Weight Resolution 

Moisture Content Display 

Moisture Content Accuracy  over 1g
(Standard Deviation)               over 5g
Heating Technology 

Drying Temperature 

(1

°

C increment)

Memory of Measurement Programs 

Measurement Programs 

Measurement Mode 

Heating Mode

Display Type 

Interface 

Data  Memory Function

Operating Temperature 

GLP/GMP/ISO 

Self Check Function 

Communication Software 

Sample Pan Size 

Power 

Physical Dimention/Weight 

Standard Accessories 

20 sets

100

WinCT-Moisture standard

400W straight halogen lamp heating system with SRA filter

and SHS weighing technology

Halogen lamp (Straight type, 400 Watt max, 5000 hours) 

Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode 

Moisture content(Wet or Dry base) /Dry content/Ratio/Weight 

Large VFD 

RS-232C standard 

5-40

°

C (41-104

°

F) less than 85%RH

Available 

Standard 

Ø85mm 

AC 100V to 120V (3A) or AC 200V to 240V (1.5A), 50/60 Hz, Approx. 400W

215(W) x 320(D) x 173(H) / Approx. 6kg 

3-23-14 Higashi-lkebukuro, Toshima-ku,Tokyo 170-0013 JAPAN
Telephone:[81](3) 5391-6132 Fax:[81](3) 5391-6148
http://www.aandd.jp 

1756 Automation Parkway, San Jose, CA  95131 U.S.A.
Telephone:[1](408) 263-5333 Fax:[1](408) 263-0119

32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA
Telephone:[61](8) 8301-8100 Fax:[61](8) 8352-7409

Unit 24/26 Blacklands Way Abingdon Business Park, 
Abingdon, Oxon OX14 1DY UNITED KINGDOM
Telephone:[44](1235) 550420 Fax:[44](1235) 550485

<German Sales Office>

Große Straße 13 b 22926 Ahrensburg GERMANY
Telephone:[49](0) 4102 459230 Fax:[49](0) 4102 459231

Manhattan Bldg. 8F, 36-2 Yoido-dong, Youngdeungpo-gu, Seoul, KOREA
Telephone:[82](2) 780-4101 Fax:[82](2) 782-4280

...

Clearly a Better Value

Vereyskaya str.17, Moscow, 121357 RUSSIA
Telephone: [7] (495) 937-33-44 Fax: [7] (495) 937-55-66

509 Udyog Vihar Phase V
Gurgaon-122 016, Haryana, INDIA
Telephone: [91](124) 471-5555  Fax: [91](124) 471-5599

A&D Inst

D Instruments India Pr

uments India Private 

e Limited

mited

A&D Australasia 

ia Pty 

y Ltd.

d.

Summary of Contents for MF-50

Page 1: ...Moisture Analyzers ISO 9000 CERTIFIED http www aandd jp Moisture Analyzers MS 70 MX 50 MF 50 ML 50 MS 70 MX 50 MF 50 ML 50 ...

Page 2: ...mory function According to sample up to 20 suitable measurement conditions can be stored and recalled which saves time and prevents the user from making a mistake when setting 10 for MF 5 for ML For measurement result up to 100 data can be stored and output at once 50 for MF 30 for ML Five measurement programs Five choices of measurement programs Standard Automatic Quick Timer and Manual Mode are ...

Page 3: ...lled at the bottom of the analyzer Standard RS 232C Bi directional communication with a PC or connects directly to a printer Conformity to GLP GMP GCP and ISO with date time ID calibration data and check record outputs Data output for daily record management MS MX MF ML Select the best moisture analyzer for your application Test with The Best External Calibration Super Hybrid Sensor VFD Display RS...

Page 4: ...e measurement Patent pending Shows sample data summary Provides a data summary for the sample with the results of moisture rate change for the representative material s measurement Calculates measurement data statistics Saves the recorded data as a CSV file Determines other changes to the sample material in addition to moisture rate Continuously measures changes to the mass in response to heating ...

Page 5: ...S 70 and the KF Karl Fischer method Example of PET plastic pellet measurement Soybean flour Sodium tartrate dihydrate Corn starch Sodium tartrate dihydrate WinCT Moisture consists of RsTemp software to determine the heating temperature and RsFig software for graphics MS 70 KF method Moisture rate Average value 0 298 0 307 Repeatability standard deviation 0 0045 0 0065 Average measurement time 6 8 ...

Page 6: ...er 1g Standard Deviation over 5g Heating Technology Drying Temperature 1 C increment Memory of Measurement Programs Measurement Programs Measurement Mode Heating Mode Display Type Interface Data Memory Function Operating Temperature GLP GMP ISO Self Check Function Communication Software Sample Pan Size Power Physical Dimention Weight Standard Accessories 20 sets 100 WinCT Moisture standard 400W st...

Reviews: