ANATEL Novus RHT-Air Instruction Manual Download Page 9

NOVUS AUTOMATION 

9/10 

 

Operate the device at its maximum power (14 dBm) and minimum 

sample period (15 s).  

 

Let the instrument operate continuously in the above conditions for 24 h 

while monitoring the battery voltage through reading register number 29 

or the 

Diagnostic

 menu of the 

DigiConfig

 software. 

 

If the battery voltage exceeds 3.5 V, the battery can be considered 

rehabilitated (depassivated). The device is then ready to use. 

 

In case the above does not work, please remove the battery from the 

device and  discharge it for 5 minutes connecting a 220 Ohm resistor 

across the terminals. 

 

After that, you should put the battery in the device and leave it running 

for about 2 hours. If the battery has a voltage above 3.5 V, it has been 

undone and can operate normally. 

 

If after going through the above procedures the battery still fails to work 

properly, please contact technical assistance for arranging battery 

replacement. 

IMPORTANT

 

The sensor used in this device may be damaged or de-calibrated if exposed 

to contaminated atmospheres with chemical agents. Hydrochloric acid, nitric 

acid, sulfuric acid,  and ammonia in high concentrations may damage the 

sensor. Acetone, ethanol,  and propylene glycol may cause reversible 

measurement errors. 

9

 

TROUBLESHOOTING 

9.1

 

PROBLEMS COMMUNICATING WITH THE DEVICE VIA USB 

INTERFACE OR DURING FIRMWARE UPDATE 

If you have problems communicating the device via the USB interface or 

there are problems during firmware update, it is recommended to perform the 

following procedure to  speed communication  and minimize incompatibility 

issues:  

a.

 

Open the Device Manager: 

 

Figure 14 –

 

Device Manager 

b.

 

Open the COM port setting of the device: 

 

Figure 15 –

 

Device Manager

 

 

 

 

 

 

 

 

 

c.

 

Open advanced COM port configuration options: 

 

Figure 16 –

 

Port settings configuration 

d.

 

Uncheck the 

Use FIFO buffers 

option: 

 

Figure 17 –

 

Advanced settings

 

10

 

CERTIFICATIONS 

FCC

 

Contains FCC ID: 2AXVWBAIRR-NOVUSAIR

 

This device complies with Part 15 of the FCC Rules. Operation is subject to 

the following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

NOTE:

 This equipment has been tested and found to comply with the limits 

for a Class A digital device, pursuant to part 15 of the FCC Rules. These 

limits  are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio frequency energy 

and, if not installed and used in accordance with the instruction manual, may 

cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in 

which case the user will be required to correct the interference at his own 

expense 

WARNING:

  To satisfy FCC RF exposure requirements, a separation 

distance of 20 cm or more should be maintained between the antenna of this 

device and persons during operation. To ensure compliance, operations at 

closer distances than this are not recommended. This device and its 

antenna(s) must not be co-located or operating in conjunction with any other 
This product has been tested with Wellshow AR0035EW0119N antenna. 
Changes or modifications not expressly approved by the party responsible 

for compliance could void the user’s authority to operate the equipment. 

Canada 

This Class A device complies with Canadian standard ICES-003. 

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du 

Canada. 

CE Mark 

This is a Class A product. In a domestic environment, this product may 

cause radio interference in which case the user may be required to take 

adequate measures. 

ANATEL

 

This device is homologated by ANATEL, in accordance with the procedures 

regulated by Resolution 242/2000, and meets the technical  requirements 

applied. 
This equipment is not subject to the protection from harmful interference and 

may not cause interference with duly authorized systems. 
For more information, see the ANATEL websit

www.anatel.gov.br

Summary of Contents for Novus RHT-Air

Page 1: ...NOVUS AUTOMATION 1 10 RHT Air WIRELESS DEVICE FOR TEMPERATURE RELATIVE HUMIDITY AND DEW POINT INSTRUCTIONS MANUAL V2 0x A...

Page 2: ...212 F Relative Humidity RH 0 0 to 100 0 RH No condensation Dew Point 40 C and 100 C 40 F to 212 F Measurements Accuracy See Figure 3 Note It is possible to perform an Offset adjustment using the DigiC...

Page 3: ...one through USB interface Remove the four set screws of the front panel of the RHT Air device taking the necessary precaution not to apply force on the internal connector of the electronic circuit Fig...

Page 4: ...register When it reaches values below 3 3 V a battery change must be scheduled this register may present a measurement error of up to 5 Note Even when the power is below 100 the device will operate n...

Page 5: ...y 8 Screen Dew point 7 WIRELESS COMMUNICATION RHT Air has an IEEE 802 15 4 wireless communication to connect to AirGates Modbus that has its firmware updated to a version more recent than V1 23 The fi...

Page 6: ...z 21 2455 MHz 22 2460 MHz 23 2465 MHz 24 2470 MHz 25 2475 MHz REGISTER 28 LINK QUALITY INDICATOR It serves to inform the quality of the reception link of the connection between the device and the AirG...

Page 7: ...e Modbus network This address identifies the device on the Modbus network Its configuration may range from 1 and 247 There cannot be more than one piece of device with the same address on the same net...

Page 8: ...rror value 9999 9999 R W 39 Temperature value C or F 400 1000 R 40 Relative humidity value 0 1000 R 41 Dew point value C or F 400 800 R For the abovementioned table ranges one decimal place should be...

Page 9: ...the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Page 10: ...NOVUS AUTOMATION 10 10 11 WARRANTY Warranty conditions are available on our website www novusautomation com warranty...

Reviews: