NOVUS AUTOMATION
9/10
•
Operate the device at its maximum power (14 dBm) and minimum
sample period (15 s).
•
Let the instrument operate continuously in the above conditions for 24 h
while monitoring the battery voltage through reading register number 29
or the
Diagnostic
menu of the
DigiConfig
software.
•
If the battery voltage exceeds 3.5 V, the battery can be considered
rehabilitated (depassivated). The device is then ready to use.
•
In case the above does not work, please remove the battery from the
device and discharge it for 5 minutes connecting a 220 Ohm resistor
across the terminals.
•
After that, you should put the battery in the device and leave it running
for about 2 hours. If the battery has a voltage above 3.5 V, it has been
undone and can operate normally.
•
If after going through the above procedures the battery still fails to work
properly, please contact technical assistance for arranging battery
replacement.
IMPORTANT
The sensor used in this device may be damaged or de-calibrated if exposed
to contaminated atmospheres with chemical agents. Hydrochloric acid, nitric
acid, sulfuric acid, and ammonia in high concentrations may damage the
sensor. Acetone, ethanol, and propylene glycol may cause reversible
measurement errors.
9
TROUBLESHOOTING
9.1
PROBLEMS COMMUNICATING WITH THE DEVICE VIA USB
INTERFACE OR DURING FIRMWARE UPDATE
If you have problems communicating the device via the USB interface or
there are problems during firmware update, it is recommended to perform the
following procedure to speed communication and minimize incompatibility
issues:
a.
Open the Device Manager:
Figure 14 –
Device Manager
b.
Open the COM port setting of the device:
Figure 15 –
Device Manager
c.
Open advanced COM port configuration options:
Figure 16 –
Port settings configuration
d.
Uncheck the
Use FIFO buffers
option:
Figure 17 –
Advanced settings
10
CERTIFICATIONS
FCC
Contains FCC ID: 2AXVWBAIRR-NOVUSAIR
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense
WARNING:
To satisfy FCC RF exposure requirements, a separation
distance of 20 cm or more should be maintained between the antenna of this
device and persons during operation. To ensure compliance, operations at
closer distances than this are not recommended. This device and its
antenna(s) must not be co-located or operating in conjunction with any other
This product has been tested with Wellshow AR0035EW0119N antenna.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Canada
This Class A device complies with Canadian standard ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
CE Mark
This is a Class A product. In a domestic environment, this product may
cause radio interference in which case the user may be required to take
adequate measures.
ANATEL
This device is homologated by ANATEL, in accordance with the procedures
regulated by Resolution 242/2000, and meets the technical requirements
applied.
This equipment is not subject to the protection from harmful interference and
may not cause interference with duly authorized systems.
For more information, see the ANATEL website