15
14
Using the two switches between the Program and Select buttons on the front panel, you can
select whether a 2-stage or 3-stage charging profile is used to charge the batteries and control
the battery charger’s behavior when the charging cycle ends.
Front Panel Adjustments
The End-of-Charge (EOC) select switch controls the charger’s behavior after it finishes charg-
ing the battery/ batteries.
Setting the switch to Rest:
• Causes the unit to remain in rest mode after finishing the recharge cycle. The charger
will remain like this until it detects that the battery voltage has dropped <90% of the
rated voltage. It will then initiate a new recharge cycle.
• The charger will also initiate a new recharge cycle if power to the unit is disconnected or
cycled.
• This EOC Select Switch MUST be in the Rest position for the unit to meet the California
Energy Commission regulations.
Setting the switch to Float:
• Causes the unit to maintain the battery at the float voltage indefinitely. This will ensure
that the battery is always fully recharged and ready for use.
• A new recharge cycle will only be initiated if the charger is proving its full rated current
to keep the battery at float, or if the power is disconnected or cycled.
END-OF-CHARGE SELECT