Analog Devices Hittite HMC-T2000 User Manual Download Page 29

 

HMC-T2000  User’s Manual                                                                                        HMC119983 Rev 1 
 

27

 

 

11.  The calibration software has completed the calibration procedure. Select OK to close the 

application, and recycle power on the HMC-T2000.  

Programming 

The enclosed CDROM contains the necessary control software and drivers to support a 
smooth installation with a Windows XP operating system. Also included is a Programmer’s 
Reference Guide which provides the primary software commands, GUI source codes and C 
language support that permits customized control compatible with Labview or LabWindows 
routines. 

Technical Support 

Please contact 

[email protected]

 or call (978) 250-3343 and request the HMC-

T2000 technical support department.  Hittite Microwave provides local direct support in 
many areas around the world.  Please see the “Contact Us” page at www.hittite.com. 

Warranty 

Seller warrants to Buyer that Seller’s standard product instrumentation goods delivered hereunder will 
conform to the applicable specifications and certifications and be free of defects in material and 
workmanship for a period of one (1) year from the date of shipment to the Buyer.

 The warranties stated 

herein are in lieu of all other warranties, expressed, implied, or statutory and of all other obligations or liabilities 
on the part of Seller. Buyer expressly waives any right, claim, or cause of action that might otherwise arise out 
of the purchase and use of seller’s products or service. Seller shall not be liable for special or consequential 
damages of any nature with respect to any merchandise or service sold, delivered, or rendered No product is 
warranted to be fit for any particular use or application, and no warranty is made that any set of standards will 
be met other than what is marked on the product. Seller warrants all parts of merchandise of its manufacture to 
be free from defects caused by faulty material or poor workmanship. Liability is limited to the obligation to repair, 
or, to replace without charge Ex-Works Chelmsford, MA any part found to be defective under normal use and 
service within the warranty period provided: (1) Seller is promptly notified within the warranty period in writing 
upon discovery or such defects; (2) the original product is returned to Seller with Seller’s prior authorization, 
transportation charges prepaid; and (3) Seller’s examination shall disclose to its satisfaction that such defects 
have not been caused by abuse after delivery. Seller reserves the right to impose a reasonable charge on 
Buyer for evaluation and repair of returned goods under certain conditions. The full text of the instrumentation 
warranty and returns warranty can be found in the on-line Hittite Microwave Terms and Conditions of Sale 

http://www.hittite.com/content/documents/terms.pdf

 

10 

Appendix 

Please see the HMC-T2000 specification sheet for further information. 

 

Summary of Contents for Hittite HMC-T2000

Page 1: ...Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED www analog com www hittite com...

Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 3: ...l Synthesized Signal Generator Hittite Model HMC T2000 Hittite Microwave Corporation 20 Alpha Road Chelmsford MA 01824 Tel 978 250 3343 Fax 978 250 3373 E mail sales hittite com Internet http www hitt...

Page 4: ...n to a situation relating to the equipment set up operating or maintaining the equipment which if not observed could result in permanent damage to sensitive microwave devices or other electronic compn...

Page 5: ...mage claims to the transporter Remove the documentation packet and any other separately supplied components before attempting to remove the SG unit from the shipping container It is highly recommended...

Page 6: ...10MHz REF 10MHz TCXO POW ER REG USB REF OUT FRONT PANEL REF IN RF OUT 5VDC 15VDC 15VDC Figure 1 HMC T2000 Block Diagram 4 Installation of Equipment and Safety The bulleted guidelines shown below must...

Page 7: ...etup and Operation Before the SG unit can be operated external coaxial cables equipment and instrumentation are required to be set up The instruction steps listed below must first be completed 1 Use a...

Page 8: ...tor for the RF output See figure 2 for a view of the front panel The rear panel of the unit contains power On Off switch LCD contrast adjustment and the connectors for the External Reference Input Ref...

Page 9: ...ment frequency with 1 MHz steps 2 Increment Decrement frequency with 10 MHz steps 3 Increment Decrement frequency with 100 MHz steps 4 Increment Decrement Output Power with 0 5 dBm steps Rotation of t...

Page 10: ...s below for descriptions and illustrations of the power level indicators 5 2 3 2 Un calibrated Output Power The character is displayed next to the power level when the output power selected by the use...

Page 11: ...he RF Output ON OFF status indicator See figure 6 below Figure 6 Minimum output power indicator 5 2 4 USB Connector The USB connector is located on the rear panel The USB interface is compliant with U...

Page 12: ...specified in the datasheet on the Hittite website 5 2 5 2 External Reference The internal reference can be overridden by connecting an external reference to the BNC connector located on the rear pane...

Page 13: ...5 non condensing Altitude Less than 3000 meters Table 4 Environmental Operating Conditions 5 4 Air Inlet The unit utilizes convection cooling Please ensure that the vent openings are not obstructed or...

Page 14: ...y be accessed by pointing to the GUI and performing a Right Click with the mouse The functions available from this menu are ReMap Hardware Open Close Refresh and Disable Power Checks The top right pul...

Page 15: ...r after the application has been started use the ReMap Hardware function to force the software to check for other synthesizers 5 5 4 Remote and Local Lockout The Remote and Local Lockout feature is en...

Page 16: ...ication The Remote and Local Lockout checkbox must be selected in order for any of the sweep functions to be enabled 5 5 8 1 Single Sweep Start Continuous Sweep When the Single Sweep button is pressed...

Page 17: ...provided to enter the value of the Dwell Time for each step in the sweep Valid values for this field are 0 001 secs to 3600 secs The value may be entered by typing the desired value or using the up a...

Page 18: ...HMC T2000 User s Manual HMC119983 Rev 1 16 Select Next This window will be displayed during the install process This window shows status of the install...

Page 19: ...HMC T2000 User s Manual HMC119983 Rev 1 17 The software is being installed Select Continue Anyway...

Page 20: ...HMC T2000 User s Manual HMC119983 Rev 1 18 Select Finish Select Next...

Page 21: ...983 Rev 1 19 Select the desired folder name and location and select whether you want anyone who uses this computer to be able to run the application The default folder location is recommended Select N...

Page 22: ...HMC T2000 User s Manual HMC119983 Rev 1 20 This window is displayed to show installation progress Select Close...

Page 23: ...HMC T2000 User s Manual HMC119983 Rev 1 21 Select OK Select the Program Group for installation Hittite is the recommended group...

Page 24: ...ge the install directory if desired and then select the large button on the top left It is recommended that the installation is to the default directory This window indicates that the installer for th...

Page 25: ...progress Select Close The installation of all software components is done 6 Maintenance The unit should be calibrated every 12 months The unit is provided with calibration software so that the user c...

Page 26: ...ied with a Hittite software application to support the calibration of the unit s output power A picture of the GUI is shown in figure 8 The software will provide information related to the required eq...

Page 27: ...amount of attenuation between at the output of the HMC T2000 and the Power Meter 6 Verify power is ON to the HMC T2000 and select Initialize T2000 and verify the following window appears 7 Select OK...

Page 28: ...HMC T2000 User s Manual HMC119983 Rev 1 26 Select OK Select OK Select OK 10 Select Yes to begin calibration...

Page 29: ...aim or cause of action that might otherwise arise out of the purchase and use of seller s products or service Seller shall not be liable for special or consequential damages of any nature with respect...

Reviews: