QUICK START GUIDE
1.
Download the hot swap and power monitor software from
user guide
for more information).
2.
Connect the mini evaluation board (
to the isolation board (
) using the
8-way connector and a Micro-MaTch ribbon cable.
3.
Connect the isolation board (
) to a PC
through the 10-way connector and the
dongle. The blue LED, labeled ISO, on the isolation board
illuminates.
4.
Connect the power supply to the mini evaluation board
(
) using thick wires.
5.
To confirm that the boards are configured correctly, set the
output of the power supply to 48 V with less than a 1 A
current limit and with no load capacitance. If the boards
are configured correctly, the green LEDs, labeled
D_PWRGD on the
on the
, illuminate.
6.
Press the RESTART push-button on the mini evaluation
board (
). The green LEDs, labeled
D_PWRGD and PWRGD, both turn off, and then turn
back on after 10 sec.
7.
You can use the SHDN2 switch and SHDN push-button on
the isolation board (
) to turn off
the hot swap.
8.
If a latch event occurs (for example, a short circuit during
operation), the red LED, labeled LATCH, illuminates on
the isolation board (
). The latch
event can be cleared with a CLEAR FAULT PMBus command
or by pressing the DELATCH push-button.
9.
Disable the hot swap using the
Hot Swap Control
section
of the
Basic Operation
tab of the GUI. Disabling the hot
swap should turn off the green LEDs (D_PWRGD and
PWRGD) on both the mini evaluation board and the
isolation board.
10.
Manually program the sense resistor value and the ADC
input resistor divider values (for example, R
SENSE
= 1.5 mΩ,
ADC top = 200 kΩ, ADC bottom = 2.8 kΩ). There is no
EEPROM available on the mini evaluation board (
); therefore, these values must be
programmed each time the software GUI is opened.
11.
Check that the voltage and current measurements are as
expected in the
Power Monitor