R e v 1 . 1
| Page
32
Running a Packet Error Rate Test
To run a packet error rate test the previous section, Simple Rx / Tx Test in Packet Mode, must first be followed. Once
interrupts are observed, on both the Rx and Tx software instances, the Packet Error Rate (PER) test may be used.
Configuring the Receiver board for the PER test
1.
Once all of the Receiver and packet parameters are setup correctly (as in
Rx Setup in Packet Mode
section)
then select the “
PER
” Tab.
(
Figure 39
point
(
1
))
2.
Select the “
Rx Board Setup
” Tab
(
Figure 39
point (
2
))
3.
Set the number of packets to be received, “
No. of Packets to Rx
”
(
Figure 39
point
(
3
))
4.
Write these settings to the uC by clicking “
Write Rx Settings
”
(
Figure 39
point
(
4
))
5.
To begin the test and put the receiver into Rx click “
Begin PER Rx
”
(
Figure 39
point
(
5
))
(Note: The receiver will remain in Rx waiting for a packet to be transmitted from a valid transmitter.)
6.
If at any time you wish to terminate the test manually press “
Stop Test
”.
(
Figure 39
point
(
6
))
(Note: The test will stop automatically once it receives the final transmitted packet.)
Figure 39
Summary of Contents for EVAL-ADF7023DBxZ
Page 5: ...R e v 1 1 Page 5 4 Click Next Figure 3 Figure 3 5 Click Next Figure 4 Figure 4 ...
Page 7: ...R e v 1 1 Page 7 8 Click Next Figure 7 Figure 7 9 Click Next Figure 8 Figure 8 ...
Page 10: ...R e v 1 1 Page 10 15 Click Finish Figure 13 Figure 13 ...
Page 41: ...R e v 1 1 Page 41 Figure 43 Separate PA and LNA Matches Board Schematic DB1Z DB3Z ...
Page 42: ...R e v 1 1 Page 42 Figure 44 Combined PA and LNA Match Board Schematic DB2Z DB4Z ...
Page 43: ...R e v 1 1 Page 43 Figure 45 Separate PA and LNA Matches Board Silkscreen DB1Z DB3Z ...
Page 44: ...R e v 1 1 Page 44 Figure 46 Combined PA and LNA Match Board Silkscreen DB2Z DB4Z ...
Page 46: ...R e v 1 1 Page 46 ...
Page 47: ...R e v 1 1 Page 47 ...
Page 48: ...R e v 1 1 Page 48 ...
Page 49: ...R e v 1 1 Page 49 ...