UG-1533
Rev. 0 | Page 13 of 31
Click
Enable Status Bits
to enable the content of the status header
(see Label 9 in Figure 24). Status bits can be clocked out at the
end of the conversion data using six extra clocks when enabled.
Click
Span Compression
to enable the µModule span
compression feature (see Label 10 in Figure 24). In single-supply
applications, the use of span compression increases the
headroom and footroom available to the ADC driver by
reducing the input range 10% from the top and bottom of the
range while still accessing all available µModule codes.
Click
High-Z Mode
to enable
the internal high-Z mode (see
Label 11 in Figure 24). Enabling this mode allows the low input
current for the µModule and improves total harmonic
distortion (THD) performance.
Click
Normal Mode
to toggle to
Turbo Mode
to enable this
mode and run the µModule at a full throughput of 2 MSPS (see
Label 12 in Figure 24).
Click
Read Register
to enable features such as span
compression, high-Z mode, turbo mode, an overvoltage
condition (a sticky bit), and the status bits (see Label 13 in
Figure 24).
Click
Enable Status Bits
(see Label 9 in Figure 24) to
enable the
six status bits. The content of the six bits is updated and displayed
in the
Status Header
section (see Label 14 in Figure 24) after
clicking
Single Capture
or
Continuous Capture (
see Label 6 in
. Note that the overvoltage clamp flag status bit
updates on a per conversion basis.
When the
Busy
indicator is lit, the user must wait until the
software completes the data analysis (see Label 15 in Figure 24).
To exit the software, select
File
>
Exit
.
Within any of the chart panels, the tools shown in Table 4 allow
the user to control the different chart displays.
Table 4. Graphical User Interface (GUI) Tools
Symbol
Description
This tool controls the cursor, if present.
This tool zooms in and out.
This tool is used for panning.
The
ADAQ400x evaluation board software
allows the user to
export the raw data or image. Right click any of the five capture
tabs (
Waveform
,
Histogram
,
FFT
,
INL_DNL
, and
Summary
) to
open the window shown in Figure 27. The user can either
export raw data to Excel or save an image as a .BMP, .EPS, or
.EMF format.
202
1
1-
020
Figure 27. Export Raw Data or Image