EVAL-AD7605-4SDZ/EVAL-AD7606SDZ/EVAL-AD7607SDZ/EVAL-AD7608SDZ User Guide
UG-851
Rev. A | Page 5 of 15
EVAL-AD7606-4SDZ
The
EVAL-AD7606-4SDZ
evaluation board is supplied with the
AD7606-4
mounted at U1 (see Figure 1).The
AD7606-4
is a 4-
channel DAS with simultaneous sampling ADC. External signals
can be applied to V1, V2, V5, and V6. Input Connectors V5 and
V6 route to the
AD7606-4
V3 and V4 input channels,
respectively.
EVAL-AD7605-4SDZ
The
EVAL-AD7605-4SDZ
evaluation board is supplied with the
AD7605-4
mounted at U1 (see Figure 1)The
AD7605-4
is a 4-
channel DAS with a simultaneous sampling ADC. External signals
can be applied to V1, V2, V5, and V6. Input Connectors V5 and
V6 route to
AD7605-4
V3 and V4 input channels, respectively.
Table 3. Link Options
Link
Default Position
Function
LK1
A
This link is used to select the power supply source for the evaluation board.
In Position A, the board can be powered by the supplied wall mounted switching supply using the J1
connector.
In Position B, the evaluation board must be powered by an external supply connected to the J3 terminal block.
LK2
Insert
LK2 supplies the SDP power supply from the evaluation board.
The
EVAL-SDP-CB1Z
is powered from the
ADP7104
5 V linear regulator.
LK3
B
LK3 is used to select the V
DRIVE
source for the
AD7606
/
AD7606-6
/
AD7606-4
,
AD7607
,
AD7608
, and
AD7605-4
.
In Position A, the
AD7606
/
AD7606-6
/
AD7606-4
,
AD7607
,
AD7608
, and
AD7605-4
are supplied with 3.3 V V
DRIVE
.
In Position B, the
AD7606
/
AD7606-6
/
AD7606-4
,
AD7607
,
AD7608
, and
AD7605-4
are supplied with 5 V V
DRIVE
,
5 V V
DRIVE
runs the device at 200 kSPS in serial interface mode.
SL1
A
In Position A, the CS signal is supplied from the SDP terminal, J2.
In Position B, The CS SMB is selected.
SL2
A
In Position A, the SCLK signal is supplied from the SDP terminal, J2.
In Position B, the SCLK SMB is selected.
SL3
A
In Position A, the STBY signal is supplied from the SDP terminal, J2.
In Position B, the STBY SMB is selected.
SL4
A
In Position A, the CS signal is supplied from the SDP terminal, J2.
In Position B, the CS SMB is selected.
SL5
A
In Position A, the RESET signal is supplied from the SDP terminal, J2.
In Position B, the RESET SMB is selected.
SL6
A
In Position A, the CS signal is supplied from the SDP terminal, J2.
In Position B, the CS SMB is selected.
SL7
A
In Position A, the CONVST signal is supplied from the SDP terminal, J2.
In Position B, the CONVST SMB is selected.