EVAL-AD7175-8SDZ User Guide
UG-901
Rev. 0 | Page 5 of 10
SOCKETS AND CONNECTORS
Table 2. Connector Details
Connector
Function
Connector Type
Manufacturer
Manufacturer
Number
Order Code
1
J1
Connector to the
120-way connector,
0.6 mm pitch
Hirose
FX8-120S-SV(21)
FEC1324660
A0 to A3
Analog inputs to the ADC
Straight PCB mount
SMB/SMA jack
Tyco
1-1337482-0
Not applicable
J3
External bench top voltage supply for
the
Power socket block,
3-pin, 3.81 mm pitch
Phoenix
Contact
MC 1,5/ 3-G-3,81
FEC3704757
J4
External ac-to-dc adapter input for the
, 7 V to 9 V
DC power
connectors, 2 mm
SMT power jack
Kycon
KLDX-SMT2-
0202-A
MOUSER 806-
KLDX-SMT20202A
J5
External bench top voltage supply
option for AVDD1/AVDD2 and IOVDD
inputs on the
Screw terminal
block, 3.81 mm pitch
Phoenix
Contact
MKDS 1/4-3.81
FEC3704592
J8
GPIO terminal
Power socket block,
4-pin, 3.81 mm pitch
Phoenix
Contact
MC 1,5/ 4-G-3,81
FEC3704749
J10 and
J12
Analog input terminal block; wired
connection to external source or sensor
Power socket block,
8-pin, 3.81 mm pitch
Phoenix
Contact
MC 1,5/ 8-G-3,81
FEC3704774
J14
Analog input terminal block; wired
connection to external source or sensor
Power socket block,
6-pin, 3.81 mm pitch
Phoenix
Contact
MC 1,5/ 6-G-3,81
FEC3704762
J15
Optional header
7-way, 2.54 mm pin
header
Samtec
SSW-107-01-T-S
FEC1803478
J16
Optional header
7-way, 2.54 mm
socket
Samtec
TLW-107-05-G-S
FEC1668499
1
Order codes starting with FEC are for Farnell.
SERIAL INTERFACE
The
evaluation board connects to the
on the SDP-B controller board via the
serial peripheral interface (SPI). There are four primary signals,
CS, SCLK, and DIN (all inputs), and one output from the ADC,
DOUT/RDY.
To operate the evaluation board in standalone mode, disconnect
the
serial interface lines from the 120-pin header by
removing the 0 Ω, R9 through R13 links. Use the test points to
connect the signals to an alternative digital capture setup.
POWER SUPPLIES
Power the evaluation board from the ac-to-dc adapter
connected to J4, or from an external bench top supply applied
to J3 or J5. Linear LDOs generate the required voltages from the
applied input voltage (V
IN
) rail when using J3 or J4. Use J5 to
bypass the on-board regulators. The regulators used are the 5 V
fixed output voltage and 2.5 V adjustable output voltage
devices, which supply the AVDD1 and AVDD2 rails
(3.3 V) supplies the IOVDD rail. Use
the
(5 V) to supply 5 V for the SDP-B controller
board. Each supply is decoupled where it enters the board and
again at each device. Table 3 shows the various power supply