background image

EVAL-AD7175-8SDZ User Guide 

UG-901 

 

Rev. 0 | Page 9 of 10 

DATA SECTION 

Data Waveform 

The data waveform shows each successive sample of the ADC 
output. The toolbar in the graph allows the user to zoom in on 
the data. Change the scales on the graph by typing values into 
the x-axis and y-axis. 

Display Units 

Click 

Display Units

 to select whether the data graph displays in 

units of voltages or codes. 

Vref 

Vref

 sets the reference voltage used for calculating the results on 

the data graph. The user must update this value when the reference 
source changes, because it does not automatically update. 

Autoscale 

Autoscale

 enables and disables the y-axis autoscale control for the 

data graph. With this control enabled, the graph automatically sets 
the maximum and minimum y-axis values to fit the displayed data. 

X-scale and X-scale Samples 

These controls set the number of data points displayed on the  
x-axis. When set to fixed, the number of data points is equal to 
the number in the 

X-scale Samples

 numeric input. This control 

automatically updates each time 

Start Sampling

 is clicked. 

When set to dynamic, all samples are displayed, including those 
from previous sample batches. 

Channel Selection 

This control allows the user to choose which channels display 
on the data waveform. It also shows the analog inputs for that 
channel labeled next to the on and off controls. These controls 
only affect the display of the channels and do not have any 
effect on the channel settings in the ADC register map. 

Latest Data 

These indicators show the value of the last sample gathered on 
the corresponding channel (see 

Channel Selection

).  

ANALYSIS SECTION 

Analysis Histogram and Analysis Channel 

The histogram shows the analysis of the channel selected via the 
analysis channel drop-down box. This graph only shows the 
histogram for one channel at a time. 

Analyse Last # Samples 

This is the number of samples used for creating the histogram 
analysis. This is automatically set to equal the number of 
samples when 

Start Sampling 

is clicked. 

Analysis Results 

This section displays the results of the histogram analysis for 
the selected analysis channel. This includes both noise and 
resolution measurements. 

STATUS 

The status section at the bottom of the window display status 
updates such as 

Analysis Completed

 and 

Reset Completed

 

during software use. 

EXITING THE SOFTWARE 

To exit the software, click the close button at the top, right 
corner of the main window (see Figure 7). 

SAVING RESULTS 

The software can save the current captured data for later 
analysis.  
1.

 

Right-click the waveform graph. 

2.

 

Click 

Export

 in the drop-down menu. 

3.

 

Select the folder for the data to be saved into and the name 
of the file you want to save. 

4.

 

Click 

Save

The data is saved in the format selected for display units via the 

Display Units

 option. 

 

Summary of Contents for EVAL-AD7175-8SDZ

Page 1: ... on the information therein All referenced brands product names service names and trademarks are the property of their respective owners 00000005981LF 000 EOS Power Buy Now We have 45 000 LP502030 PCM NTC LD A02554 EEMB Lithium Battery Rectangular 3 7V 250mAh Rechargeable in stock now Starting at 0 034 This EEMB part is fully warrantied and traceable 1 855 837 4225 Give us a call International 1 5...

Page 2: ...board connects to a USB port via the SDP B system demonstration platform controller board EVAL SDP CB1Z The AD7175 8 evaluation software fully configures the AD7175 8 device functionality via a user accessible register interface and provides dc time domain analysis in the form of waveform graphs histograms and associated noise analysis for ADC performance evaluation Full specifications on the AD71...

Page 3: ...oise Test 3 Evaluation Board Hardware 4 Device Description 4 Hardware Link Options 4 Sockets and Connectors 5 Serial Interface 5 Power Supplies 5 Power Supply Configurations 6 Analog Inputs 6 Reference Options 6 Evaluation Board Software 7 Software Installation 7 Launching the Software 7 Software Operation 8 Overview of the Main Window 8 Control Toolbar 8 Data Section 9 Analysis Section 9 Status 9...

Page 4: ... B board to the PC via the USB cable For Windows XP you may need to search for the SDP drivers Choose to automatically search for the drivers for the SDP B board if prompted by the operating system 6 From the Analog Devices subfolder in the Programs menu launch the AD7175 8 software QUICK START NOISE TEST Use the following procedure to quickly test the noise performance 1 Insert Link LK5 to Link L...

Page 5: ... the following Position A AIN1 REF2 pin on the AD7175 8 Position B Buffer U6 Position C U7 for use with a single ended to differential driver circuit Position D J15 7 SL2 A Routes A2 to one of the following Position A AIN2 pin on the AD7175 8 Position B Buffer U10 Position C U9 for use with a single ended to differential driver circuit SL3 A Routes A3 to one of the following Position A AIN3 pin on...

Page 6: ...t MC 1 5 6 G 3 81 FEC3704762 J15 Optional header 7 way 2 54 mm pin header Samtec SSW 107 01 T S FEC1803478 J16 Optional header 7 way 2 54 mm socket Samtec TLW 107 05 G S FEC1668499 1 Order codes starting with FEC are for Farnell SERIAL INTERFACE The EVAL AD7175 8SDZ evaluation board connects to the Blackfin ADSP BF527 on the SDP B controller board via the serial peripheral interface SPI There are ...

Page 7: ...ed in Table 1 Split Supply Regulated To set up the board use the following procedure 1 Remove SL12 to SL15 These links connect AVSS to AGND 2 Connect a bench top power supply to J3 and set LK2 to Position A Make sure that AVSS 2 5 V in this case 3 Set LK1 to Position B This sets the input to the power monitor circuitry to work with the lower AVDD1 supply of 2 5 V Set all other links and solder lin...

Page 8: ...ers Installation Confirmation Dialog Box After installation is complete connect the EVAL AD7175 8SDZ evaluation board to the EVAL SDP CB1Z SDP B board as shown in Figure 2 Connect the SDP B board via the USB cable to the computer Take the following steps to verify that the SDP B controller board driver is installed and working correctly 1 Allow the Found New Hardware Wizard to run 2 After the driv...

Page 9: ...in the graphs of the DATA and ANALYSIS sections of the main window The Samples numeric control is the number of samples gathered per batch Sampling Sampling set to Capture in Figure 7 enacts the sampling mode used by the software This is unrelated to the ADC mode The user can capture a defined sample set or continuously gather batches of samples In both cases the number of samples set in the Sampl...

Page 10: ...inputs for that channel labeled next to the on and off controls These controls only affect the display of the channels and do not have any effect on the channel settings in the ADC register map Latest Data These indicators show the value of the last sample gathered on the corresponding channel see Channel Selection ANALYSIS SECTION Analysis Histogram and Analysis Channel The histogram shows the an...

Page 11: ...ny other party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTIONS Customer may not disassemble decompile or reverse engineer chips on the Evaluation Board Customer shall inform ADI of any occurred damages or any modifications or alterations it makes to the Evaluat...

Reviews: