background image

Evaluation Board User Guide 

UG-154 

 

Rev. 0 | Page 3 of 16 

INERTIAL SENSOR EVALUATION SYSTEM SETUP

DOWNLOADING ALL FILES TO A PC 

Before proceeding with the installation routine, it is important 
to first download all files included on the ADXRS800 install-
ation CD-ROM to a local folder on the host PC. Browse to a 
destination directory on the host PC and right click to select 

New/Folder

. Name this folder, and copy the CD-ROM files into 

this new location. You are now ready to begin the installation 
routine. 

ISEB HARDWARE SETUP 

Before connecting the ISEB hardware to the PC via the included 
USB cable, drivers must be installed so that the PC properly 
recognizes the ISEB main board. The USB drivers for the ISEB 
are available in the /

ISEB_USB

/ folder on the packaged CD. 

Installing the USB Drivers for the ISEB 

To install the USB drivers, follow these steps: 
1.

 

Execute the 

ADI_ISEB_USB_Drivers.exe

 file located in 

/

ISEB_USB

/.  

2.

 

Follow the on-screen instructions to install the drivers. 

3.

 

Click 

Continue Anyway

 when prompted that the drivers 

are not tested. 

After the above steps are complete, you can connect the ISEB 
main board to the computer via the included USB cable. If the 
previously installed drivers are not automatically associated 
with the device, you may need to select the drivers manually, as 
follows: 
1.

 

Connect the USB A to Mini-B cable to the PC and then to 
the ISEB. The satellite board does not need to be connected 
for this step. New hardware is detected upon completion of 
this step.  

2.

 

If prompted to install drivers again, click 

Install from a list 

or specific location (Advanced) (

see Figure 2); then click 

Next

.  

09113-

002

 

Figure 2. Found New Hardware Prompt 

3.

 

Select 

Don’t search. I will choose the driver to install

 (see 

Figure 3), and click 

Next

4.

 

Select 

ADI Inertial Sensor Evaluation System

 from the 

model list (see Figure 4), and click 

Next

 to complete the 

process. 

The ISEB should be detected automatically in the

 Device 

Manager 

as the 

ADI Inertial Sensor Evaluation System

 under 

the 

Ports (COM & LPT)

 

selection. It is recommended to open 

the 

Device Manager

 to verify hardware detection and to record the 

communication port associated with the ISEB for use in the GUI. 

09113-

003

 

Figure 3. Selection of the Driver to Install 

09113-

004

 

Figure 4. Selection of the ADI Inertial Sensor Evaluation System Drivers 

COM PORT VERIFICATION 

Installing the latest firmware revision, as well as operating the 
ADXRS800 evaluation GUI, requires that you know the 
communications port that is assigned to the ISEB main board. 
With the ISEB main board connected to the PC, you should 
perform the following steps to determine the assigned COM 
port number. 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for ADXRS800

Page 1: ...onmental chamber for temperature or humidity testing Separating the boards mitigates corruption of data due to the temperature and humidity effects of other components The ISEB is a universal main boa...

Page 2: ...ng the Latest ISEB Firmware 4 Hardware Configuration 7 Inertial Sensor Evaluation System Graphical User Interface 8 Getting Started 8 View and Record Data Panel 9 Temperature Test Panel 10 Noise and R...

Page 3: ...need to select the drivers manually as follows 1 Connect the USB A to Mini B cable to the PC and then to the ISEB The satellite board does not need to be connected for this step New hardware is detec...

Page 4: ...ed COM port of the ISEB hardware The Device Manager window should look like the window shown in Figure 6 09113 007 Figure 7 System Properties INSTALLING THE LATEST ISEB FIRMWARE The latest ISEB firmwa...

Page 5: ...nd release SW2 c Release SW1 The download begins and is automatically verified by the downloader 2 If the downloading process fails which is indicated in the Monitor Status box see Figure 8 attempt th...

Page 6: ...ent is displayed 3 Read the license agreement before accepting it then click Next The installer lists the required components to install on your PC see Figure 13 4 To start the installation click Next...

Page 7: ...alternate high voltage supplies see the ADXRS800 data sheet and the Alternate External High Voltage Supply section of this guide ANALOG DEVICES ADXRS800 SATELLITE DEFAULT JUMPER POSITIONS CONNECTOR 0...

Page 8: ...o the Analog Devices inertial sensor evaluation system Select this COM port from the drop down menu and click Confirm COM to begin using the GUI After the COM port is confirmed the full functionality...

Page 9: ...indefinitely Secondary information that is transmitted along with the plotted signals is graphically represented This includes the fault register sequence bits status bits and sensor module bits This...

Page 10: ...llow for an indefinite length for data recording Before recording the data on this panel you can adjust for null offset components Note that any offset correction made to the ADXRS800 is stored in the...

Page 11: ...e free environment Any rotational rate input into the gyroscope can greatly degrade the validity of the resulting RAV plot Determining the rms noise of the ADXRS800 can be done on this same panel The...

Page 12: ...Stability button You are then prompted to enter a file name for the data upon completion of the specified number of turn on cycles or upon clicking the Stop Data Record button While the test is runni...

Page 13: ...avior of the ADXRS800 for incorporation into your system s algorithms For this test panel the first SPI message is typically received from the device within 20 ms after the ISEB supplies power to the...

Page 14: ...llite board through 180 90 can also be used Because the satellite board is approximately square as each adjacent side is brought flush with the straight edge 90 of rotation will have been experienced...

Page 15: ...bed in detail in the ADXRS800 data sheet The main requirement for the external high voltage supply is that 0 1 mA to 1mA of current be supplied to the device The nominal internal voltage is 22 5 V As...