MANUAL REGISTER WRITE TAB
The
Manual Register Write
tab (see Figure 37) allows manual
writes to the
registers, either individually (
Values to
write
) or grouped (
Load and Write
). In the
Load and Write
section, click
Choose Input File
to load a list of register writes
from a file or paste one into the field directly. Click
Write All
to
send the list to the ADAR1000-EVALZ.
When the device is initially powered up, enter 00099 into the
Values to write
section. Entering 00099 performs a full register
reset and enables the 4-wire SPI SDO function.
READBACK TAB
The
ReadBack
tab allows direct writing and reading of the
content of a register (see Figure 38).
Click
Manual Write
to write a string of hexadecimal digits
containing the address and data of a register into the register.
Enter the register address in the
Register
field and click
Manual
Read
for the content of the register to display in the
Data
field.
16
788
-01
5
Figure 37.
Manual Register Write
Tab
1
678
8-
0
16
Figure 38.
ReadBack
Tab