background image

AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for 
three (3) years from the date of purchase from AMX Corporation, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch 
overlay components that are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are 
warranted for a period of one (1) year.

Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.

Software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.

AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This 
includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable 
for any claim made by a third party or by an AMX Dealer for a third party.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim 
(including negligence and strict product liability), a contract claim, or any other claim. This limitation of 
liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX 
Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such dam-
ages. This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or 
exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of 
the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also 
have other rights that vary from state to state. The owner is advised to consult applicable state laws for full 
determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO 

OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION 

EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY 

IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS 

LIMITED WARRANTY.

Summary of Contents for UPC20 Plus

Page 1: ...Operation Reference Guide Control System Accessories UPC20 Universal Power Controller Last Revised 09 12 2007...

Page 2: ...liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limita...

Page 3: ...le disconnect device shall be incorporated into the fixed wiring An insulated earthing conductor that is identical in size insulation material and thickness to be earthed and unearthed branch circuit...

Page 4: ......

Page 5: ...wer Control mode 5 Remote Sensor Control mode 5 Channel codes Remote Sensor mode 6 Installation 7 P1 Terminal Connections 7 P2 Terminal Connections 7 Control Mode 7 High Voltage Wiring Options 10 Sing...

Page 6: ...ii UPC20 Universal Power Controller Table of Contents...

Page 7: ...to protect the motor A timing adjustment potentiometer is user adjustable for automatic release of the relays The range is 0 to 90 seconds 1 2 and 3 button control modes are selectable In Power Contr...

Page 8: ...E INSIDE COVER FOR DETAILED WIRING NOTE NO HIGH VOLTAGE THIS CONNECTION AND DIP SWITCH INFORMATION IN 4 8 CONTROL INPUT INPUTS GND 3 DATA 2 GND 4 4 3 IN 1 IN 2 5 6 IN 3 7 CONTACT 12 9 REMOTE C R IND C...

Page 9: ...o theP1 Terminal Connections section on page 7 Set switch S1 to the line input voltage value used before applying power to the UPC20 High Voltage Terminal Block P1 High voltage input and output wiring...

Page 10: ...0 seconds It is typically set to allow direction limit switches to operate or to reach the desired position Single Button Mode operates with one pushbutton in a sequence Up Stop Down Stop and so on fo...

Page 11: ...his allows up to 8 UPC20 and IR sensors to be used in the same room without interfering with one another It is possible to control 2 separate UPC20 s with one handheld remote control The 4th switch of...

Page 12: ...de Sw 1 Sw 2 Sw 3 Sw 4 Radio Code UPC20 Off Off Off Off 0 First On Off Off Off 1 First Off On Off Off 2 First On On Off Off 3 First Off Off On Off 4 First On Off On Off 5 First Off On On Off 6 First O...

Page 13: ...is 20 Amps There are two 12 gauge jumpers that are wired to supply board power at 120 240 VAC and to connect the common terminals of the relays The jumpers are removed as needed according to the wiri...

Page 14: ...d 2 off after time out Motor Momentary Off On Off On Minimum Push 1 load 1 on Release 1 load 1 off Push 2 load 2 on Release 2 load 2 off Maximum Push 1 load 1 on Release 1 load 1 off Note No delay on...

Page 15: ...Push 2 again load 2 off Release 2 again load 2 still off Power Momentary 1 Latch ing 2 Minimum Push 1 load 1 on Release 1 load 1 still on Push 1 again load 1 off Release 1 again load 1 still off Push...

Page 16: ...er Two Button On Off Off On Minimum Push 3 load 1 off Release 3 load 1 still off Push 4 load 2 off Release 4 load 2 off Maximum Push 3 load 1 off Release 3 load 1 still off Push 4 load 2 off Release 4...

Page 17: ...circuit protected and the output supplies up to 25 mA for the remote sensor For dual circuit 277 VAC operation remove both 12 AWG wire jumpers FIG 6 Low voltage and 277 VAC high voltage wiring 1 2 3...

Page 18: ...ts 4 Install conduit Provide conduit for high voltage low voltage and control wiring requirements using the 0 5 inch or 0 75 inch conduit connector knockouts 5 Connect high voltage wiring to the termi...

Page 19: ...Installation 13 UPC20 Universal Power Controller...

Page 20: ......

Page 21: ...BELGIUM BRAZIL CANADA CHINA ENGLAND FRANCE GERMANY GREECE HONG KONG INDIA INDONESIA ITALY JAPAN LEBANON MALAYSIA MEXICO NETHERLANDS NEW ZEALAND PHILIPPINES PORTUGAL RUSSIA SINGAPORE SPAIN SWITZERLAND...

Reviews: