Troubleshooting
20
PT10-PLV Single Camera Pan/Tilt System
Setting the RS-232 DIP Switch (S2)
If you are experiencing communication problems with the AXB-EM232, check the
communications settings for the device. The RS-232 communication parameters for this device are
set via the eight-position RS-232 DIP switch. On the AXB-EM232, the RS-232 DIP switch is
located on the front panel. Verify that this DIP switch is set to the default positions indicated in
below.
The following describes the RS-232 DIP switch default positions:
The following table lists the RS-232 DIP switch settings:
• 9,600 baud
• No parity
• 8 bits
• 1 stop bit
RS-232 DIP Switch (S2) Settings
Position
1
2
3
4
5
6
7
8
Function Stop Bits Data Bits
Parity
Baud Rate
Off
Off
Off
Off
Off
Off
Off
Off
2 bits
7 bits
Unused
300
On
On
On
Off
Off
On
Off
Off
1 bit
8 bits
Unused
600
Off
On
Off
Off
On
Off
Unused
1,200
On
On
Off
On
On
Off
Unused
2,400
Off
Off
On
Off
Off
On
Unused
4,800
On
Off
On
On
Off
On
Even
9,600
Off
On
On
Off
On
On
Odd
19,200
On
On
On
On
On
On
None
38,400
Summary of Contents for PT10-PLV
Page 1: ...instruction manual Camera Control Systems PT10 PLV Single Camera Pan Tilt System ...
Page 4: ...ii PT10 PLV Single Camera Pan Tilt System Table of Contents ...
Page 26: ...Troubleshooting 22 PT10 PLV Single Camera Pan Tilt System ...
Page 28: ...Sony Technical Support 24 PT10 PLV Single Camera Pan Tilt System ...
Page 29: ......
Page 30: ......
Page 31: ...Sony Technical Support 27 PT10 PLV Single Camera Pan Tilt System ...