Restoring the Factory Default Settings

You can restore the factory default settings on the NXV-CPI by pressing the pushbutton 

on the front panel and holding it down for 10 seconds. FIG. 4 displays the location of 

the Restore Factory Defaults pushbutton.

Configuration

The NXV-CPI provides a web-based configuration interface to set up networking and 

NetLinx settings as well as phone UI layout. You can make various configuration 

settings via a web browser on any PC that has access to the NXV-CPI device. Entering 

the device’s IP address in an enabled browser (Microsoft Internet Explorer, Mozilla 

Firefox, and Apple Safari for PCs, and Firefox and Safari for Macintoshes) allows the 

device to be accessed in that browser. Once contact is established, and a username and 

password entered, the Configuration pages may be reached and used to create phone 

screens. The default username for the configuration interface is 

administrator

 and the 

default password is 

password

.

Determining the IP Address of the NXV-CPI

NXV-CPI units feature a built-in zero-configuration networking client that allows you to 

determine the unit’s IP address via a client that uses the Zero Configuration Networking 

Standard. Zero Configuration (or Zeroconf) technology provides a general method to 

discover services on a local area network. In essence, it allows you to set up a network 

without any configuration, as described below.

Zero-Configuration Client

You will need a zero-configuration client to determine the IP address of the NXV-CPI. 

Many zero-configuration clients are currently available. However, for the purposes of 

this document, we will refer to Bonjour for Windows, which is Apple's implementation of 

the Zero Configuration Networking Standard. It is free and widely available for 

download.

Note: Bonjour and Bonjour for Windows are trademarks of Apple Inc., registered in the 

U.S. and other countries.

If you don’t already have it installed on your PC, download and install Bonjour for 

Windows before you begin.
Perform these steps to log on to the NXV-CPI through Bonjour for Windows:
1.

With Bonjour for Windows running on a PC that has access to the LAN on which 

the NXV-CPI resides, connect the NXV-CPI to the network.

2.

In Bonjour, you will see the unit join the network at power up. Double-click the 

NXV-CPI link to access the NXV-CPI Login page.

3.

To log on to the system, enter the following user name and password:

Username

: administrator

Password

: password

Screen Manager

The Screen Manager features pages that describe the layout and button IDs for the 

phone display. The Screen List page displays a listing of all available screen pages. You 

can add, edit, or delete screen pages from this page (FIG. 5).

Note: Clicking Set Default for a screen page sets the page as your main page on your IP 

phone screen.

Adding a New Screen

Perform the following steps to add a new screen page:
1.

Select 

Screen List

 from the Screen Manager menu to open the Screen List page.

2.

Click 

Add Screen

. The New Screen Creation page opens.

3.

Enter the name you want for the page in the 

Page Name

 field.

4.

Enter a description in the 

Description

 field.

5.

Select the page type from the 

Select Page Type

 options menu. You can choose 

from List, Info Text, and Text Input.

6.

Click 

Accept

, and the corresponding Edit Screen appears based on the page type 

you selected.

Note: The following special characters are not available for use in the Web Configuration 

Interface: ~, `, !, #, %, ^, %, +, =, |, \, :, <, >, /, [, and ]. Any special characters not in 

this list are available for use.

Editing Screen Pages

After creating a new screen, you can edit the settings for the screen to establish refresh 

rates and assign address and channel codes for individual buttons. 
There are three different types of screen pages you can edit: 

List

Info Text

, and 

Text 

Input

. FIG. 6 displays the Info Text page. The List and Text Input pages are similar and 

vary only slightly from the Info Text page.

Import Screens

The Import Screen Definition File page enables you to browse for a zipped screen 

definition file. Click 

Browse

 to locate a screen definition file from an accessible network 

location, and click 

Accept

.

Export Screens

The Export Screens option enables you to save a zipped screen definition file. Select 

Export Screens from the Screen Manager menu, and navigate to the location into which 

you want to save the file.

Cisco Configuration Assistant

In the Cisco Configuration Assistant, you must add the sub-menu 

/nxv-cpi

 to the IP 

address in the Services Menu Access field.

Additional Documentation

Refer to the 

NXV-CPI Operation/Reference Guide

 (available at 

www.amx.com

) for 

complete configuration information.

FIG. 4  

RESTORE FACTORY DEFAULTS PUSHBUTTON

FIG. 5  

SCREEN MANAGER - SCREEN LIST

Restore Factory 

Defaults 

pushbutton

Edit button

Delete button

FIG. 6  

EDIT SCREEN - INFO TEXT PAGE

The NXV-CPI supports address and channel codes from 1-255

Enter a text value for a button

Use a page flip to move to a specified page