Installation

5

 Mio Modero Device Family

Installation

The basic front and rear components of the Mio Modero are as follows:      

Before touching the device, discharge the static electricity from your body by touching 
a grounded metal object.

FIG. 2  

Mio Modero Front and Rear Components

AxLink
3.5 mini Phoenix
connector

Notch to pry
faceplate free

(Rear Single)

Installation Button

Slot to pry
button free

8 position mini
DIP switch

Screw
holes

(Front Single)

Screw
holes

AxLink
3.5 mini Phoenix
connector

8 position mini
DIP switch

(Rear Double)

Notch to pry
faceplate free

PWR+

PWR+

Summary of Contents for Mio Modero Classic

Page 1: ...Operation Reference Guide Control System Accessories Mio Modero Device Family Last Revised 09 05 2008...

Page 2: ...or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its products or for the failure of its...

Page 3: ...he AMX SOFTWARE including without limitation any if any service packs or hot fixes provided to Licensee after the expiration of the ninety 90 day Limited Warranty period are not covered by any warrant...

Page 4: ......

Page 5: ...iring 8 Preparing captive wires 8 Wiring guidelines 9 Connecting the Wiring 9 AxLink Data and Power Connections 9 Using AxLink for data with an auxiliary power supply 10 Mounting Procedures 11 Wallbox...

Page 6: ...ii Mio Modero Device Family Table of Contents...

Page 7: ...s Mio Modero Device Family Classic Engraved plastic buttons with a red active feedback LED in the upper left corner Prestige Clear plastic capped buttons with laser printed inserts a red active feedba...

Page 8: ...1 kg 50 lbs 23 kg Operating Environment Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 10 to 70 C 14 to 158 F Mounting Mounts into US and a majority of International single gang back...

Page 9: ...ling it to act as a button Fixed Menu System Using the KeypadBuilder application available for download from www amx com the LCD can be programmed with a Fixed Menu System FMS that is navigated via th...

Page 10: ...Overview 4 Mio Modero Device Family...

Page 11: ...rom your body by touching a grounded metal object FIG 2 Mio Modero Front and Rear Components AxLink 3 5 mini Phoenix connector Notch to pry faceplate free Rear Single Installation Button Slot to pry b...

Page 12: ...the button using the slot on the front of the installation buttons to remove them from the Mio Modero 2 Select the location of the custom buttons and snap them into place Be sure to note the orientat...

Page 13: ...anual available at www amx com Mio Modero Prestige The Mio Modero Prestige ships with sheets of common menu items and icons for creating inserts for single and double buttons 1 If connected disconnect...

Page 14: ...r and data Preparing captive wires You will need a wire stripper and flat blade screwdriver to prepare and connect the captive wires 1 Strip 0 25 inch 6 35 mm of wire insulation off all wires 2 Insert...

Page 15: ...m of 13 5 volts available Connecting the Wiring The following paragraphs describe wiring connections for using the AxLink and relay connectors AxLink Data and Power Connections Connect the control sys...

Page 16: ...s the limits described in Wiring Guidelines table Connect only the GND wire on the AxLink connector when using an auxiliary 12 VDC power supply FIG 7 AxLink and 12 VDC power supply wiring diagram PWR...

Page 17: ...dero AMX recommends mounting the Mio Modero in a standard one gang wallbox a conduit box per NEC specs section 370 with a minimum internal clearance of 2 5 8 x 1 3 4 x 1 5 8 HWD but it is possible to...

Page 18: ...Connect the AxLink power supply The connector passes through the center of the mounting frame and connects to the board The connection is illustrated in FIG 2 5 Place the mounting frame on the wallbo...

Page 19: ...f the Mio Modero and pry the faceplate from the mounting frame 4 Connect the AxLink power supply The connector passes through the center of the mounting frame and connects to the board The connection...

Page 20: ...cific wallbox 3 Confirm that the terminal end of the AxLink cable is disconnected and not receiving power 4 If the faceplate is connected to the mounting frame place a flathead screwdriver in the notc...

Page 21: ...tions Power 12 vDC 15 mA Receive Frequencies 38 and 455 kHz Range 38KHz transmitter at 38Hz max of 95 feet line of sight transmitter at 38Hz and at 50 horizontal angle from center 55 feet transmitter...

Page 22: ...witch values shown below The device number is set by the total value of DIP switch positions that are ON up As an example the DIP switch in FIG 13 defines device number 129 1 128 129 If you later chan...

Page 23: ...For wire prepartaion guidelines refer to Preparing captive wires section on page 8 Checking AxLink Status The AxLink LED shown in FIG 12 lights to indicate AxLink power data status as follows If the L...

Page 24: ...d not receiving power 3 If the faceplate is connected to the mounting frame place a flathead screwdriver in the notch at the bottom right of the Mio Modero IR and pry the faceplate from the mounting f...

Page 25: ...Mio Modero IR 19 Mio Modero Device Family FIG 16 Attaching the faceplate to the mounting frame...

Page 26: ...Mio Modero IR 20 Mio Modero Device Family...

Page 27: ...etLinx master All text is based on a Unicode index SEND_COMMANDs BRT Set Brightness level Syntax BRIT tag awake brightness level sleep brightness level Variables brightness level a value from 0 32 tag...

Page 28: ...range 1 4 the address range corresponds to the dynamic line number S Static line type Example SEND_COMMAND Panel FML 1 S Sets dynamic line 1 to a menu line FML D Sets a line of the display to a dynami...

Page 29: ...ber glyph number glyph text Example SEND_COMMAND Panel GLY 1 4 2 Sets the second glyph character on dynamic lines 1 and 4 of the LCD button JST LCD equipped only Set text alignment using a numeric key...

Page 30: ...END_COMMAND Panel SLEEP 45 Forces the device into screen saver mode after 45 seconds SSL Sends a string to the master upon going to sleep Syntax SSL new text Variables new text 1 20 ASCII characters D...

Page 31: ...s 1 and 3 of the LCD button 2 SEND_COMMAND Panel TXT 2 4 Clear text on dynamic lines 1 through 4 of the LCD button UNI LCD equipped only Set Unicode text The Unicode text is sent as a two byte HEX val...

Page 32: ...etLinx Studio 2 Go to Tools Firmware Transfers Send to Axcess Device This opens the Send to Axcess Dialog Window 3 Browse to the location of the firmware file 4 Select the file within the Files frame...

Page 33: ...Programming The Mio Modero 27 Mio Modero Device Family...

Page 34: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Reviews: