Installing the HPX-1600
21
HPX-1600 Retractable Connection Port
Step 8 - Install the Retaining Ring
1.
Insert the four #6-32 x 1 3/8 retaining screws into the retaining ring.
Note the orientation of the retaining ring. This orientation changes in order to accommodate the various
thicknesses of mounting surfaces (see FIG. 8 on page 11).
2.
Place the retaining ring over the lower portion of the base assembly and against the underside of the
mounting surface.
3.
If an accessory mounting bracket HPX-AC-MB (FG559-21) is to be used, install it now by trapping it
between the retaining ring and mounting surface (FIG. 19).
4.
Gradually tighten the four retaining screws to secure the unit in the mounting surface.
Ensure the unit is properly aligned in the mounting surface.
Torque the retaining screws to approximately 3 in-lbs.
Do not over tighten the screws.
5.
After tightening the retaining screws ensure the unit moves smoothly up and down.
Over tightening the retaining screws can cause the system to bind.
If the system binds, gradually loosen the retaining screws until it operates smoothly.
FIG. 20 on page 22 shows the HPX-1600 Unit installed in to the mounting surface:
Note the direction of the screw bosses.
For mounting surfaces less than 35mm thick, orient the screw bosses away form
the main assembly (down).
For mounting surfaces greater than 35mm thick orient the screw bosses toward the
main assembly (up).
FIG. 19
Installing HPX-AC-MB Accessory Mounting Brackets
HPX-AC-MB
Accessory Mounting
Bracket
HPX-AC-MB
Accessory Mounting
Bracket