Upgrading Firmware
29
MXD/T-700 7" Modero X Series® Touch Panels
5.
Click the
Edit Settings
button on the
Communications Settings
dialog to open the
Virtual NetLinx Master
Settings
6.
Within this dialog, enter the
Master System number
. The default is
1
.
7.
In the
Available Connections
section, click on the IP address for the touch panel to select it.
8.
In the
Virtual NetLinx Master Settings
dialog box, click
OK
to close the box.
9.
In the
Communications Settings
dialog box, click
OK
to close the box.
10.
In the
Master Communications Settings
dialog box, click
OK
to save your settings and return to the main
NetLinx Studio application.
11.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the Virtual System.
The
default System value is 1
.
12.
Right-click on the
Empty Device Tree/System
entry and select
Refresh System
to re-populate the list.
13.
The OnLine Tree should now display the connection to the device. The
Connection Status
Icon on the
device may take up to five seconds to register the connection.
FIG. 29
Virtual NetLinx Master Settings
The panel will not appear as a device below the virtual system number, in the
Online
Tree
tab, until both the system number used in step 14 for the Virtual NetLinx Master
is entered into the Master Connection section of the
System Settings
page and the
panel is restarted.
Summary of Contents for FG5968-04
Page 4: ......
Page 28: ...Installation 22 MXD T 700 7 Modero X Series Touch Panels ...
Page 30: ...Configuration and Programming 24 MXD T 700 7 Modero X Series Touch Panels ...
Page 38: ...Upgrading Firmware 32 MXD T 700 7 Modero X Series Touch Panels ...
Page 40: ...Appendix Troubleshooting 34 MXD T 700 7 Modero X Series Touch Panels ...
Page 41: ...Appendix Troubleshooting 35 MXD T 700 7 Modero X Series Touch Panels ...