WebConsole - System Options
51
NetLinx Integrated Controllers (Firmware v4)- WebConsole & Programming Guide
Creating and Recalling Diagnostics Presets
The
Store
and
Recall
options in the Edit Options window allow you to save and recall preset diagnostics configurations.
NOTE:
Presets are saved via cookies, so they do not persist across multiple browsers/computers.
1.
Click the
Presets
down arrow to open a list of previously stored Presets. By default, the only preset is called
0: All Devices, All
Notifications
. This default Preset cannot be modified.
2.
Select an empty Preset (for example
1:
)
3.
Select the desired diagnostic options, and click
Store
.
4.
A popup window prompts you to name this Preset. Enter a name and click
OK
.
To recall an existing Preset, select it from the drop-down list and click on
Recall
.
NOTE:
A Preset MUST be Recalled before clicking the Update button. If you do not press this button, none of the fields or checkboxes
are modified or selected. In essence, all options become disabled.
Manage System - Server Options
Click the
Server
link (in the
Manage System
tab) to access the Server Options page (FIG. 55). The options on this page allow you to:
Change the port numbers (used by the Master for various Web services)
Configure the SSL settings used on the Master
Manage existing and pending license keys, manage the active NetLinx system communication parameters
Configure/modify the SSL certificates on the target Master
The options on this page are described below:
Port Settings
Allows a user to modify the server settings; specifically those port assignments associated with individual services.
All items can be either enabled/disabled via the
Enabled
checkboxes.
The port number values (except the FTP port) can be modified in this page.
The default port for each service is listed to the right.
Server Port Settings
The following table describes each of the Port Settings presented on this page:
FIG. 55
Server Options page
Server Port Settings
Feature
Description
Telnet:
The port value used for Telnet communication to the target Master. Enabling this feature allows future communication with
the Master via a separate Telnet application (such as HyperTerminal).
• The default port value is
23
.
• Refer to the
NetLinx Security with a Terminal Connection
section for more information on the related procedures.