Using NetLinx Studio
21
DXP-HT v1.3 - On-Site Installer’s Guide
Therefore, it is recommended that the IP Address be set to a Static Address. To do this:
1.
Verify that NetLinx appears in the
Host Name
field.
2.
Click the
Specify IP Address
radio button from the IP Address section.
3.
Enter the
IP Address
,
Subnet
Mask
, and
Gateway
information into their respective fields.
4.
Click the
Set IP Information
button to retain a known IP Address (obtained from the System
Administrator) on the specified System Master.
5.
Click
OK
to accept the new changes.
6.
Click the
Reboot Master
button and select
Yes
to close the Network Address dialog. This
process closes the Network Addresses dialog and directs you to the Reboot the Master
Controller dialog.
7.
Click
Continue
(from the Reboot Controller dialog) and wait for the System Master to reboot
and retain the newly obtained DHCP Address. The STATUS and OUTPUT LEDs should begin
to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to
blink.
8.
Right-click associated System number and select Refresh System. This establishes a new
connection to the specified System and populates the list with devices on that system.
Addressing the System
The NetLinx NXI system used by DXP-HT consists of two devices: a Master and (serial ports,
relays, IR ports, and I/O ports). Each is addressed separately on the NetLinx bus with a unique
device ID. There is no need to modify the device ID of the Master unless the system is being
installed in a multi-Master system. However, the device ID of the NXI may need to be changed.
DXP-HT expects this device ID to be 5001:1:0.
To modify device IDs in NetLinx the current ID must be known so it can be directly told to change
to a new device ID. To determine the current device ID of the NXI use the online tree in NetLinx
Studio to view a list of all the current online devices the Master recognizes. This list will show the
device ID and the type of device. Find the one that identifies itself as "NXI", and note its device ID.
To change the system ID:
1.
Right-click on any System item listed in the OnLine Tree tab of the Workspace and select
Device Addressing (from the pop-up list) or
Select Diagnostics > Device Addressing
from the
Main menu.
2.
Select the
Change System
selection box, from the
System to Change
section.
3.
Enter both the current and new system address values. Enter the new device ID,
5001
, in the
Change To Device
field.
4.
Click the
Change Device/System Number
button. This configures the Master to accept the
new value and incorporate the information. Your online tree should change to reflect the new
ID of the NXI. The system information (in the OnLine Tree tab of the Workspace window)
refreshes and then displays the new information.
5.
Click
Done
to close the Device Addressing dialog and return to the main program.
6.
Select
Tools > Reboot the Master Controller
to access the Reboot the Master dialog, then
click
Continue
to reboot the Master and incorporate any changes. Allow 20 - 30 seconds for
Summary of Contents for DESIGN XPRESS HOME THEATER V1.3 - ON SITE INSTALLER GUIDE
Page 1: ...instruction manual Software Design XPress Home Theater version 1 3 On Site Installer s Guide...
Page 16: ...On Site Installer s Guide Overview 12 DXP HT v1 3 On Site Installer s Guide...
Page 22: ...Understanding the Report File 18 DXP HT v1 3 On Site Installer s Guide...
Page 28: ...Using NetLinx Studio 24 DXP HT v1 3 On Site Installer s Guide...
Page 29: ...Using NetLinx Studio 25 DXP HT v1 3 On Site Installer s Guide...