
Device Configuration Software
49
Novara 3000 Series ControlPads Instruction Manual
10.
Select
Red
from the Color menu, and select
1
from the Toggle Level menu on the right side of the window
(FIG. 65).
11.
Click
Add
to add the event to the script.
12.
Select
Green
from the Color menu, and select
2
from the Toggle Level menu on the right side of the window.
13.
Click
Add
to add the event to the script.
14.
Click Button 3 on the ControlPad interface.
15.
Select
Button Behavior
in the Content area, and set the Action Type is set to Toggle.
16.
Set the
Max # of Toggles
option to 3.
17.
Select
Buttons
in the Content area.
18.
Select
Red
from the Color menu, and select
1
from the Toggle Level menu on the right side of the window.
19.
Click
Add
to add the event to the script.
20.
Select
Green
from the Color menu, and select
2
from the Toggle Level menu on the right side of the window.
21.
Click
Add
to add the event to the script.
22.
Select
Blue
from the Color menu, and select
3
from the Toggle Level menu on the right side of the window.
23.
Click
Add
to add the event to the script.
24.
Click Button 4 on the ControlPad interface.
25.
Select
Button Behavior
in the Content area, and set the Action Type is set to Toggle.
26.
Set the
Max # of Toggles
option to 4.
27.
Select
Buttons
in the Content area.
28.
Select
Red
from the Color menu, and select
1
from the Toggle Level menu on the right side of the window.
29.
Click
Add
to add the event to the script.
30.
Select
Green
from the Color menu, and select
2
from the Toggle Level menu on the right side of the window.
31.
Click
Add
to add the event to the script.
32.
Select
Blue
from the Color menu, and select
3
from the Toggle Level menu on the right side of the window.
33.
Click
Add
to add the event to the script.
34.
Select
White
from the Color menu, and select
4
from the Toggle Level menu on the right side of the window.
35.
Click
Add
to add the event to the script.
36.
Click Button 5 on the ControlPad interface.
37.
Select
Advance Toggle
in the Content area, and select button 4 from the Button menu.
38.
Select
2nd
from the Advance to option buttons.
39.
Click
Add
to add the event to the script.
40.
Click
Program Devices
to program the scripts on the selected ControlPads.
The ControlPad should do the following:
Pressing Button 1 causes the button to turn red.
Pressing Button 2 causes the button to turn red. Pressing it again turns the button green.
Pressing Button 3 causes the button to turn red. Pressing it again turns the button green. Pressing it a third
time turns the button blue.
Pressing Button 4 causes the button to turn red. Pressing it again turns the button green. Pressing it a third
time turns the button blue. Pressing it a final time turns the button white.
Pressing Button 5 then pressing Button 4 turns Button 4 green.
FIG. 65
Toggle Level menu
Toggle Level menu
Summary of Contents for CP-3006
Page 6: ...iv Novara 3000 Series ControlPads Instruction Manual Table of Contents ...
Page 30: ...Button Labeling 24 Novara 3000 Series ControlPads Instruction Manual ...
Page 68: ...Device Configuration Software 62 Novara 3000 Series ControlPads Instruction Manual ...
Page 75: ...RMS Configuration 69 Novara 3000 Series ControlPads Instruction Manual ...