Wiring and Device Connections
13
Novara 3000 Series ControlPads Instruction Manual
RELAYS
You can connect up to two independent external relay devices to the Relay connectors on the device. Connectors labeled
A
are for
Common
and
B
are for
Output
(FIG. 15).
Each relay is isolated and normally open.
24 V
DC
@ 1 A maximum
28 V
AC
@ 1 A maximum
I/O
The I/O port (FIG. 16) responds to switch closures and voltage level (high/low) changes, or can be used for logic-level
outputs. The PWR pin pr12 VDC @ 200 mA and is designed as a power output for the PCS Power Current
Sensors, VSS2 Video Sync Sensors (or equivalent). The GND connector is a common ground and is shared by all I/O
ports. A common ground is shared with I/O ports 1 - 2.
Inputs are contact closure sensing. Input voltage is as follows:
HIGH (no contact closure): V
IH
> 2.5 V
DC
LOW (contact closure): V
IL
< 0.8 V
DC
Output voltage is as follows:
V
OH
= +3.3 V
DC
+/- 0.3 V
DC
(internal 25k Ohm pull-up resistor)
V
OL
= 0 V
DC
+/- 0.3 V
DC
(200 mA maximum sink current)
The following table provides wiring requirements for the I/O port:
IR
You can connect up to two IR-controllable devices to the IR connectors (FIG. 17).
The IR connectors support generating carriers up to 1.142 MHz. The IR connectors accept an IR Emitter (CC-NIRC)
that mounts onto the device's IR window, or a mini-plug (CC-NSER) that connects to the device's control jack.
You can also connect a data (0 - 5 V
DC
) device.
FIG. 15
RELAYS connectors
FIG. 16
I/O connectors
I/O Port Wiring Specifications
Signal
Function
+12 V:
PWR
1:
Output
2:
Output
GND:
Signal GND
FIG. 17
IR/SERIAL connectors
Summary of Contents for CP-3006
Page 6: ...iv Novara 3000 Series ControlPads Instruction Manual Table of Contents ...
Page 30: ...Button Labeling 24 Novara 3000 Series ControlPads Instruction Manual ...
Page 68: ...Device Configuration Software 62 Novara 3000 Series ControlPads Instruction Manual ...
Page 75: ...RMS Configuration 69 Novara 3000 Series ControlPads Instruction Manual ...