AXP-CCV/AXM-CCV Color Video Camera Centers
Installation
17
Using AXM-CCV AXlink connector for data and an external 12 VDC power
supply
Connect the control system’s AXlink connector to the AXlink connector on the rear
panel of the AXM-CCV as shown in Figure 19.
PWR +
AXM
AXP
GND -
PWR +
AXM
AXP
GND -
AXlink connector
Control system
12 VDC power supply
PWR +
GND -
Use an external 12 VDC power supply when the distance between the control system
and AXM-CCV exceeds the limits described in Figure 15. Make sure to connect only
the GND wire on the AXlink connector when using an external 12 VDC power
supply. Do not connect the PWR wire to the AXlink connector’s PWR (+) terminal.
Using a BNC video cable to provide video input
Connect the control system’s video connector at the rear panel of the AXM-CCV and
AXP-CCV to the video source as shown in Figure 20.
Video Source
Front
cable
view
GND -
Video wire
BNC (female) connector
BNC (male ) connector(s)
Rear panel view
AXP-CCV
Figure 19
AXlink and external 12 VDC
power supply, and control
system wiring diagram
Figure 20
BNC video cable- wiring
diagram
Note
This example is for the back of
the AXP-CCV.