background image

AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three 

(3) years from the date of purchase from AMX Corporation, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch 
overlay components that are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one 
(1) year.

AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting 
products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the 
control of dimmable loads that are properly connected to our lighting products. The dimming performance or 
quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers.

Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.

AMX Software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.

All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is 

obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. 

The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received 

not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products 

returned without a valid RMA number.

AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. 

This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not 

liable for any claim made by a third party or by an AMX Dealer for a third party.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort 

claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of 

liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corpo-

ration or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. 

This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or 

exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of 

the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may 

also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full 

determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO 

OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION 

EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY 

IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS 

LIMITED WARRANTY.

Summary of Contents for AXC-232

Page 1: ...instruction manual Axcess Control Cards AXC 232 RS 232 422 485 Control Card ...

Page 2: ... RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform This includes any lost profits lost savings incidental damages or consequential damages AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a...

Page 3: ... 232 422 DIP Switch 2 Setting the Internal Jumpers 2 Enabling RS 232 Mode 2 Card Edge Pinouts 3 Preparing captive wires 3 Using RS 232 4 Using Hardware Handshaking 4 Using RS 422 4 Using RS 485 4 Programming 5 Send_Commands 5 Send_Strings 6 Send_String escape sequences 6 Axcess Master Mode 6 ...

Page 4: ...ii AXC 232 RS 232 422 485 Card Table of Contents ...

Page 5: ...G 1 AXC 232 RS 232 422 485 Control Card Specifications Power Requirement 125 mA 12 VDC RS232 422 DIP Switch An eight position DIP switch used to set the communication parameters for the card Refer to the RS 232 422 DIP Switch section on page 2 for more informa tion Asynchronous data standards Baud rates 300 600 1200 2400 4800 9600 19200 and 38400 Data bits 7 8 and 9 Stop bits 1 and 2 Parity None O...

Page 6: ...ata Bits Parity Baud Rates Setting Off Off Off Off Off Off Off Off Value 2 bits 7 bits Unused 300 On On On Off Off On Off Off 1 bit 8 bits Unused 600 Off On Off Off On Off Unused 1 200 On On Off On On Off Unused 2 400 Off Off On Off Off On Mark 4 800 On Off On On Off On Even 9 600 Off On On Off On On Odd 19 200 On On On On On On None 38 400 ON 1 2 3 4 5 6 7 8 RS232 422 Static electricity can damag...

Page 7: ...strip the threads and damage the connector FIG 3 JP2 Internal Jumper 232 485 mode Card Edge Pinouts Pin Signal Function 1 GND Ground RS 232 2 RX Receive data RS 232 3 TX Transmit data RS 232 4 12V Power 5 RX Receive data RS 422 6 RX Receive data RS 422 7 TX Transmit data RS 422 8 TX Transmit data RS 422 9 GND Ground 10 CTS Hardware handshaking Clear to send 11 RTS Hardware handshaking Ready to sen...

Page 8: ...5 Using RS 422 When communicating via RS 422 connect the wiring as shown in FIG 6 Using RS 485 When communicating via RS 485 connect the wiring as shown in FIG 7 FIG 4 RS 232 wiring FIG 5 Hardware handshaking wiring FIG 6 RS 422 wiring FIG 7 RS 485 wiring RX TX GND AXC 232 Device TX RX RX TX TX RX GND 12V RTS CTS RTS CTS 1 2 3 4 AXC 232 Device TX RX RX AXC 232 Device TX RX TX TX RX TX RX GND 12V G...

Page 9: ...nd status on channel 255 for CTS hardware handshake input See CTSPSH above EOFF default Disables the EON command described below EON Intended for RS 485 mode this command causes characters received from the transmit ter to be ignored HSOFF default Disables hardware handshaking HSON Enables hardware handshaking RXCLR Clears any characters waiting in a receive buffer to be sent to the Master Card RX...

Page 10: ...ess device s RS 232 port Press the escape key then type either MC or MD esc MC connects the device in Master Mode esc MD disconnects the device where esc means press the Esc key Send_Strings 27 17 time Sends a break character for the specified length of time Variable time 1 255 in 100 microsecond increments 27 18 1 Sets the ninth data bit to 1 for all of the following characters to be transmitted ...

Page 11: ...Programming 7 AXC 232 RS 232 422 485 Control Card ...

Page 12: ...a doing business as Panja Inc ARGENTINA AUSTRALIA BELGIUM BRAZIL CANADA CHINA ENGLAND FRANCE GERMANY GREECE HONG KONG INDIA INDONESIA ITALY JAPAN LEBANON MALAYSIA MEXICO NETHERLANDS NEW ZEALAND PHILIPPINES PORTUGAL RUSSIA SINGAPORE SPAIN SWITZERLAND THAILAND TURKEY USA ATLANTA BOSTON CHICAGO CLEVELAND DALLAS DENVER INDIANAPOLIS LOS ANGELES MINNEAPOLIS PHILADELPHIA PHOENIX PORTLAND SPOKANE TAMPA 30...

Reviews: