8
Pre-Installation Settings
AXB-F117 Stealth 1 Camera Controller
RS-232 DIP switch (S1) settings
Position
1
2
3
4
5
6
7
8
Function
Stop Bits
Data Bits
Parity
Baud Rate
Off
Off
Off
Off
Off
Off
Off
Off
2 bits
7 bits
Unused
300
On
On
On
Off
Off
On
Off
Off
1 bit
8 bits
Unused
600
Off
On
Off
Off
On
Off
Unused
1,200
On
On
Off
On
On
Off
Unused
2,400
Off
Off
On
Off
Off
On
Unused
4,800
On
Off
On
On
Off
On
Even
9,600
Off
On
On
Off
On
On
Odd
19,200
On
On
On
On
On
On
None
38,400
Setting the AXlink Device DIP switch (S2)
The 8-position Device DIP switch (S2), shown in Figure 9, sets the AXlink device
number. The device number must match the number assigned in the AXCESS
software program. The AXlink device number range is 1-255, and is sent according
to the Device DIP switch positions and their values (Figure 10). The Device DIP
switch example shown in Figure 9 is set to 90 (2 + 8 + 16 + 64 = 90), which is the
factory default setting.
1
2 3
4 5 6 7 8
DEVICE
S2
ON
Device DIP switch (S2) settings
Position
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64
128
Figure 8
RS-232 DIP switch (S1)
settings
Note
After setting the AXlink device
number, remove and
reconnect the AXlink
connector on the AXB-F117
to store the new number into
memory.
Figure 9
AXlink Device DIP switch
(S2) example
Figure 10
Device DIP switch (S2)
positions and values