
AXB-F117 Stealth 1 Camera Controller
Pre-Installation Settings
7
Setting zoom, focus, and iris switches to servomotor or motor mode
The AXB-F117 supports servomotor (+2.5 to +7.5 VDC operating range) and direct-
drive motor (
±
6 VDC or
±
12 VDC operating range) lens control. Figure 6 shows
how to set the switches for servomotor mode (S) or motor mode (M). If you are using
a direct-drive lens, refer to the manufacturer's literature to set the VOLT switch for
±
6 or
±
12 VDC control.
Servomotor and motor voltage switch settings
Servomotor mode
Motor mode
(
±±
6 VDC)
Motor mode
(
±±
12 VDC)
VOLT
ZOOM
FOCUS
IRIS
S M
S M
S M
6 12
VOLT
ZOOM
FOCUS
IRIS
S M
S M
S M
6 12
VOLT
ZOOM
FOCUS
IRIS
S M
S M
S M
6 12
Setting the RS-232 DIP switch (S1)
The RS-232 DIP switch (S1) positions 1 and 2 set the stop and data bits, positions 3
through 5 set the parity, and positions 6 through 8 set the baud rate. Figure 7
shows the RS-232 DIP switch and Figure 8 lists their settings.
1
2 3 4 5
6 7 8
RS-232
S1
ON
Note
You must configure the AXB-
F117 software to match the
switch settings. Refer to
Configuration Commands in
the AXCESS Programming
section.
Figure 6
Servomotor and motor
voltage switch settings
Figure 7
RS-232 communications
parameters DIP switch (S1)