24
AMV OND1000-X-C1
2). Command to query the Functions No:
Format: FUNC?
After “Enter”, the unit’s “Function Code” appears on the PC screen.
3). Command to query the set value of the Function:
Format: SETT?
After “Enter”, the existing set value of the function appears on the
PC screen.
4). Command to set or adjust the value of the Function:
Format: SETT <value>
After “Enter”, the new value of the Function is set Choose the
<value> of the function as follows:
FUNC 0
: LCD Contrast
Setting Menu
SETT <value>
LCD Contrast
0~100
FUNC 1
: LCD Auto-off
Setting Menu
SETT <value>
LCD Auto-off
Disable~250
FUNC 2
: RS232 Baud rate
Setting Menu
SETT <value>
Baud rate
0
1200
1
2400
2
4800
RS-232 Baud
rate
3
9600
FUNC 3
: Buzzer Setting
Setting Menu
SETT <value>
Buzzer (Beep sound)
0
Disable
1
Shutdown
2
Alert
3
Alert , SHDN
4
Message
5
Message , SHDN
6
Message , Alert
Buzzer Setting
7
Msg , Alert , SHDN