background image

PRICE

QUERY

SET

CLEAR
CANCEL

CONFIRM

START

SALE

LITER

STOP

8

.

0

  9

1.  When fueling with preset, press this key to input the regular number
2.  When fueling model, press this key, if the sale reached the next tens integer, it will
     stop automatically.

1.   When fueling with preset, press this key to input the regular number.

2. When setting model, press this key continuously to turn on/off the screen led light

1. When fueling with preset, press this key to input the regular number
2. When fueling model, press this key, if the Liter reached the next tens integer, it will 
    stop automatically.

1. When fueling with preset, press this key as regular decimal

2. When setting model, press this key continuously to set unit price

After dispensing, or when standby, press this key to enter querying model.

1. When standby, press this key to enter setting model
2. When query model, press this key to query the previous  daily/monthly/shift total 
    fueling data.

1.When fueling with preset or setting model, input numbers by mistake. pressing this
 key to delete numbers.
2. When querying model. press this key to exit querying model
3.  When setting model, press this key to exit directly

1.When fueling with preset, input numbers first, press this key to confirm, then start 
    dispensing.
2.When setting model to change system time, unit price, sensor parameter, password 
   etc, input numbers first, then press this key to confirm and exit setting model

1.  When fueling without preset, press this key to start working.
2.  When fueling with preset, after inputting numbers, and confirm numbers, press 
     this key to start working.

When querying  model, press this key to query the next record of daily total, monthly 
total , shift total and details fueling data

1. When fueling with preset, press this key to preset desired fueling amount. I
2. When  fueling  model,  if  the  amount  reached  the  next  integer,  it  will  stop
    automatically.

1. When fueling with preset, press this key to preset desired fueling volume.

2. When fueling  model, if  the  volume  reached  the  next  integer,  it  will stop
   automatically.

Press this key to stop working

Summary of Contents for Mobile Fuel Dispenser

Page 1: ...ad carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury 12V 24V 220V FUEL DISPENSER OWNER S MANUAL ...

Page 2: ...w meter It has advantages of high accuracy abundant function high reliability easily to operate and maintenance SAFETY RULES Protective gloves Prolonged contact with hydrocarbons can cause skin irritation when dispensing fuel always use PVC gloves conforming to the standard EN 388 cat 2 Permitted uses The unit must always be used for the purpose intended Follow the instructions listed in the chapt...

Page 3: ...1 Humidity 30 C 45 C 2 Relative humidity 95 The max work ing pressure 0 3MPa Memory capacity 128kB Power DC12V DC24V AC220V AC380V Communication Protocol RS485 _ _ _ _ Working Principle Pressure oil External Power Power planes Main board Key board Encoder Nozzle SwitchI NOZZLE Flow meter Solenoid valve optional Oil container FILTER Display board Take up the automatic nozzle the signal will be tran...

Page 4: ... automobile storage battery DC12V or DC24V supply the power to the fuel dispenser The power cord is out of the fuel dispenser the red wire is for the positive terminal of the DC power supply The black wire is for negative terminal of the DC power supply Shouldn t make any mistake b The AC dispenser must be supplied by a 220V single phase alternating current line whose nominal values are shown in t...

Page 5: ...ls Accumulative volume range 9 digitals Include two decimals Accumulative amount range 11digitals C Include two decimals Unit price range 0 999 99 basic currency Liter The flow range for the advanced shutoff the valve 0 0 99 Liter Input and Outlet Interface Indicator Light Instruction Power 12v 24V 220V power indicator light Working Machine workings regularly the light sparkling Output Solenoid valv...

Page 6: ... querying model press this key to query monthly total fueling data 1 When fueling with preset press this key to input the regular number 2 When querying model press this key to query general total fueling data 1 When fueling with preset press this key to input the regular number 2 When querying model press this key to query shift total or line total fueling data 1 When fueling with preset press th...

Page 7: ...ta 1 When fueling with preset or setting model input numbers by mistake pressing this key to delete numbers 2 When querying model press this key to exit querying model 3 When setting model press this key to exit directly 1 When fueling with preset input numbers first press this key to confirm then start dispensing 2 When setting model to change system time unit price sensor parameter password etc in...

Page 8: ...assword 123456 the machine will be un locked and standby for fueling Fueling mode Fueling without preset 1 Press Start key or take up the nozzle to start fueling The display will show current dispensing volume amount and unit price 2 Put down the nozzle or press Stop key to stop fueling The display will show finished dispensed volume amount and unit price Notes Because of the display size limit the...

Page 9: ...ll take about 12 seconds so before this operation please make sure the power source is stable If 12V 24V make sure the battery has enough power If the data not cleared thoroughly then repeat the operation a When standby press SET input 9 1 the screen will display 9 1 b Input password 123456 c lnput code 91 d Press CONFIRM to start clear numbers will be jump from 1 to 100 e Machine will restart aut...

Page 10: ...ress 6 TIME key the first fueling date of current shift total will be displayed Press it again the first fueling date time and fueling times of current shift total will be displayed c Press SET or key to query the previous data and the next record d Press CLEAR CANCEL key to exit querying mode Note There will be 30 max shift total data to be kept exceeding 30 shift total data the earliest data will ...

Page 11: ...automatically on the ticket Querying mode You can query some data via the keyboard when there is no fueling in process 1 Daily Total Querying a Press QUERY key the screen board will display C then press 1 DAILY to query daily total data The default data is the nearest daily total data b Press 6 TIME key the date and serial number of current daily total data will be displayed Press it again the firs...

Page 12: ...current changing number the default changing number from YEAR f By pressing 0 9 to change the number g By pressing SET and to select the changing part h Press CONFIRM to save new system time and exit operation 6 Sensor parameter setting Warning Changing this parameter will result more or less real fuel dispensed IT IS STRONGLY SUGGESTED NOT CHANGING THIS PARAMETER a Press SET input 5 1 The screen ...

Page 13: ... Ex proof surface is intact when open the Ex proof supply power control valve and Ex proof junction box It should clean the dirty in the Ex proof chamber when re install and clean the Ex proof surface The sealing for cable should all right shouldn t loss the metal gasket and sealing Please change the sealing as soon as possible when it is aging The number for screw must be complete so that it can ...

Reviews: