The operation method

When the dispenser powers on, the whole screen of display board are checking the
field, display y.1ill show "9"   "6"   ''7"  "1"  and then will show the current date and time. It 
is in the fueling mode automatically  after 3-4seconds.

When the dispenser is standby model, the first line is the last fueling amount, the second 
line is the last fueling volume, the third line is current set unit price.

a)  Press "START" or take up the nozzle, the machine will dispense fuel.

b)  Press "STOP" or put down the nozzle, the machine will stop working.

     Note: 

By pressing "START" to start working, then press "STOP" to stop the machine.

     By taking up nozzle to start working, then put down the nozzle to stop the machine.

c) To lock the dispenser.
When standby, press 

"SET/ "    ",

 then press "STOP" three times, the dispenser will be locked,

 and it can't be operated.

Under locked situation , input password (123456), the machine will be un-locked, and 
standby for fueling.

Fueling mode:

Fueling without preset

1. Press "Start" key or take up the nozzle to start fueling. The display will show current 
    dispensing volume, amount and unit price.

2. Put down the nozzle or press "Stop" key to stop fueling. The display will show finished 
    dispensed volume , amount and unit price.

Notes: 

Because of the display size limit, the max digits for volume and amount is 

999.999.00 To make sure the dispensing data correctly, when the fueling digits reaches 
999999.00L or 999999.00 amount, the machine will stop fueling automatically. Press
 "START" key to re-start the machine.

Fueling with preset (VOLUME)
1. Press "LITER" key, then input the preset volume by press number keys of 0-9, (if input 
the wrong number, press the "CLEAR/CANCEL" key. Decimal fraction should input 
one-digit number or two-digit number after the decima point).)

2. Press "CONFIRM" key, the display will show the fueling volume. Press "START" or 
take up the nozzle to start fueling. it will stop automatically after the preset number is

Summary of Contents for Mobile Fuel Dispenser

Page 1: ...ad carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury 12V 24V 220V FUEL DISPENSER OWNER S MANUAL ...

Page 2: ...w meter It has advantages of high accuracy abundant function high reliability easily to operate and maintenance SAFETY RULES Protective gloves Prolonged contact with hydrocarbons can cause skin irritation when dispensing fuel always use PVC gloves conforming to the standard EN 388 cat 2 Permitted uses The unit must always be used for the purpose intended Follow the instructions listed in the chapt...

Page 3: ...1 Humidity 30 C 45 C 2 Relative humidity 95 The max work ing pressure 0 3MPa Memory capacity 128kB Power DC12V DC24V AC220V AC380V Communication Protocol RS485 _ _ _ _ Working Principle Pressure oil External Power Power planes Main board Key board Encoder Nozzle SwitchI NOZZLE Flow meter Solenoid valve optional Oil container FILTER Display board Take up the automatic nozzle the signal will be tran...

Page 4: ... automobile storage battery DC12V or DC24V supply the power to the fuel dispenser The power cord is out of the fuel dispenser the red wire is for the positive terminal of the DC power supply The black wire is for negative terminal of the DC power supply Shouldn t make any mistake b The AC dispenser must be supplied by a 220V single phase alternating current line whose nominal values are shown in t...

Page 5: ...ls Accumulative volume range 9 digitals Include two decimals Accumulative amount range 11digitals C Include two decimals Unit price range 0 999 99 basic currency Liter The flow range for the advanced shutoff the valve 0 0 99 Liter Input and Outlet Interface Indicator Light Instruction Power 12v 24V 220V power indicator light Working Machine workings regularly the light sparkling Output Solenoid valv...

Page 6: ... querying model press this key to query monthly total fueling data 1 When fueling with preset press this key to input the regular number 2 When querying model press this key to query general total fueling data 1 When fueling with preset press this key to input the regular number 2 When querying model press this key to query shift total or line total fueling data 1 When fueling with preset press th...

Page 7: ...ta 1 When fueling with preset or setting model input numbers by mistake pressing this key to delete numbers 2 When querying model press this key to exit querying model 3 When setting model press this key to exit directly 1 When fueling with preset input numbers first press this key to confirm then start dispensing 2 When setting model to change system time unit price sensor parameter password etc in...

Page 8: ...assword 123456 the machine will be un locked and standby for fueling Fueling mode Fueling without preset 1 Press Start key or take up the nozzle to start fueling The display will show current dispensing volume amount and unit price 2 Put down the nozzle or press Stop key to stop fueling The display will show finished dispensed volume amount and unit price Notes Because of the display size limit the...

Page 9: ...ll take about 12 seconds so before this operation please make sure the power source is stable If 12V 24V make sure the battery has enough power If the data not cleared thoroughly then repeat the operation a When standby press SET input 9 1 the screen will display 9 1 b Input password 123456 c lnput code 91 d Press CONFIRM to start clear numbers will be jump from 1 to 100 e Machine will restart aut...

Page 10: ...ress 6 TIME key the first fueling date of current shift total will be displayed Press it again the first fueling date time and fueling times of current shift total will be displayed c Press SET or key to query the previous data and the next record d Press CLEAR CANCEL key to exit querying mode Note There will be 30 max shift total data to be kept exceeding 30 shift total data the earliest data will ...

Page 11: ...automatically on the ticket Querying mode You can query some data via the keyboard when there is no fueling in process 1 Daily Total Querying a Press QUERY key the screen board will display C then press 1 DAILY to query daily total data The default data is the nearest daily total data b Press 6 TIME key the date and serial number of current daily total data will be displayed Press it again the firs...

Page 12: ...current changing number the default changing number from YEAR f By pressing 0 9 to change the number g By pressing SET and to select the changing part h Press CONFIRM to save new system time and exit operation 6 Sensor parameter setting Warning Changing this parameter will result more or less real fuel dispensed IT IS STRONGLY SUGGESTED NOT CHANGING THIS PARAMETER a Press SET input 5 1 The screen ...

Page 13: ... Ex proof surface is intact when open the Ex proof supply power control valve and Ex proof junction box It should clean the dirty in the Ex proof chamber when re install and clean the Ex proof surface The sealing for cable should all right shouldn t loss the metal gasket and sealing Please change the sealing as soon as possible when it is aging The number for screw must be complete so that it can ...

Reviews: