Document Feedback
TDC-GP30
Reference Modules and Transducers
Demo Kit Manual
• PUBLIC
UG000292
• v1-00 • 2019-Feb-26
40
│ 35
Figure 40:
Gas Meter Module, Brass
Figure 41:
Ordering Information
Ordering Code
Description
Part Number
Markup Information
(1)
t.b.d.
Gas meter module residential
IA-UGM-1
IA-UGM-1-YYYYMMDD-
SSSSSS
t.b.d.
Gas meter module industrial and
commercial
IA-UGM-2
IA-UGM-2-YYYYMMDD-
SSSSSS
(1)
YYYY = year, MM = month, DD = day, SSSSSS = product serial number that day
Figure 42:
Measurement Characteristics
Application
Residential
Commercial & Industrial
Flow Range
G1.6 to G4
G6 to G25
Flow Range Ratio
R250
R350
Accuracy Class
Class 1.5
Class 1.5
Temperature Range
-15°C to 45°C
Pressure Range
60 to 150 kPa
Sampling Frequency
0.5 to 4 Hz @ working mode
Outputs
Temperature, pressure (optional), flow under working condition and standard
condition
Auto-calibration for Gas
Yes
Compensation
Temperature and pressure
Power Consumption
< 50µA @ 4 Hz sampling rate