TROUBLESHOOTING
Problem: Sudden drop in gas
fl
ow, or a reduced
fl
ame height
Possible Cause 1:
Out of gas.
-
Call your local gas company.
Possible Cause 2:
Excess
fl
ow safety device may have been activated.
-
Turn control knob to “OFF”, wait 30 seconds and light outdoor
fi
re table. If
flames are still too low reset the excessive flow safety device by rutning off
the control knob and the gas supply. Disconnect the quick disconnect socket.
Turn the burner control knob to “HIGH”. Wait 1 minute. Turn the burner
control knob off. Reconnect the quick disconnect socket, turn on the main
gas supply and perform a leak check at the natural gas connection.
Problem: Irregular
fl
ame pattern,
fl
ame does not run the full length of the burner
Possible Cause 1:
Burner ports are clogged or blocked.
-
Clean burner ports. Do this by inserting a
paperclip in to each of the burner ports to
ensure they are not clogged.
WARNING:
Make
sure burner is not on, and has
had sufficient t
ime to cool before touching it.
Problem: Flame blow out
Possible Cause 1:
High or gusting winds.
-
Increase
fl
ame to “HIGH” setting.
Possible Cause 2:
Low natural gas pressure.
-
Call your local gas company.
Possible Cause 3:
Excess
fl
ow valve tripped.
-
Refer to “Problem: Sudden drop in gas
fl
ow”
Burner Ports
5mm
Burner Ports