AFDAU-T1 Aerial Firefighting
Data Acquisition Unit
Installation Manual
AMS-IM-1-01 Rev. 7
22 September 2021
15
2.2.10 Container Volume
When sending Fill and Drop Stop messages to the connected modem, the AFDAU-T1 will also send the volume of
water either picked up or dropped during that event.
The AFDAU-T1 can be configured for and connected to the digital outputs of several different gauging systems, the
current compatible systems are listed below:
Onboard Systems Load Cell w/ C39 Indicator
Pinouts
AFDAU-T1
J1
C39 Indicator
J1
Description
26
K
Serial Clock
8
J
Serial Data
21
L
Signal Return
Onboard Systems Load Cell w/ C40 Indicator
Pinouts
AFDAU-T1
J1
C40 Indicator
J1
Description
30*
J
RS232 TX
21*
L
Shield
* RS232 Ports 1-4 may be used of the AFDAU-T1. Port 4 is shown above.
MSI Load Cell w/ MSI-150XM Indicator
Pinouts
AFDAU-T1
J1
150XM
J1
Description
26
C
Serial Data
21
D
Signal Return