7
OL Protection: 1500 V dc/1000 V ac rms
Transient Protection: 12 kV impulse (1.2
µ
S/50
µ
S)
based on EN 61010-1:2001 impulse requirement
for at CAT IV 1000 V product. This product should
not be used in installations where transients
exceed 12 kV.
DC Current
Ranges: 200
µ
A, 2 mA, 20 mA, 200 mA, 2 A
Resolution: 0.1
µ
A
Accuracy: 200
µ
A to 20 mA: ±(0.5 % rdg+2 dgts),
200 mA to 2 A: ±(1.0 % rdg+2 dgts)
Voltage Burden: 250 mV max.
(1 mV/1
µ
A on 200
µ
A Range),
(100 mV/1 mA on 2 mA Range),
(10 mV/1 mA on 20 mA Range),
(1.5 mV/1 mA on 200 mA Range),
(500 mV/1 A on 2 A Range)
OL Protection: A Input (F 2 A/1500 V,
size 8 x 65 mm IR fast blow ceramic)
AC Current
(45 Hz to 1 kHz)
Ranges: 200
µ
A, 2 mA, 20 mA, 200 mA, 2 A
Resolution: 0.1
µ
A
Accuracy: 200
µ
A to 20 mA: ±(0.8 % rdg+4 dgts),
200 mA to 2 A: ±(1.2 % rdg+4 dgts)
Voltage Burden: 250 mV max. (1 V on 2 A range)
OL Protection: Same as DC Current.
Resistance
Ranges: 200
Ω
, 2 k
Ω
, 20 k
Ω
, 200 k
Ω
, 2 M
Ω
, 20 M
Ω
Resolution: 0.1
Ω
Accuracy: 200
Ω
±(0.5 % rdg+4 dgts),
2 k
Ω
to 200 k
Ω
: ±(0.3 %rdg+2 dgts),
2 M
Ω
: ±(1.0 % rdg+4 dgts),
20 M
Ω
: ±(2.0 %rdg+4 dgts)
OL Protection: 1500 V dc/1000 V ac rms
Open Circuit Voltage, 200
Ω
rng: 3.0 V dc typical;
all other rngs 0.3 V dc typical.
Diode/Continuity Test
Test Current: 1m A dc typical
Test/Open Circuit Voltage: 3.0 V dc Typical
Diode Accuracy: ±(1.5 % rdg +2 dgts)
Continuity Audible Threshold: < 50
Ω
± 25
Ω
Response Time: <100 msec
OL Protection: 1500 V dc/1000 V ac rms
Summary of Contents for HD110C
Page 2: ......
Page 5: ...HD110C Heavy Duty Digital Multimeter User Manual English ...
Page 18: ...12 5 ...
Page 19: ...HD110C Heavy Duty Digital Multimeter Mode d emploi Francais ...
Page 32: ...12 5 ...
Page 33: ...HD110C Heavy Duty Digital Multimeter Bedienungshandbuch Deutsch ...
Page 46: ...12 5 ...
Page 47: ...Italiano HD110C Heavy Duty Digital Multimeter Manuale d uso ...
Page 60: ...12 5 ...
Page 61: ...Español HD110C Heavy Duty Digital Multimeter Manual de uso ...
Page 74: ...12 5 ...
Page 75: ...Svenska HD110C Heavy Duty Digital Multimeter Anvandärhandbok ...
Page 88: ...12 5 ...
Page 89: ......
Page 90: ......