16
SPECIFICATIONS
Display
3-5/6 digits 6000 counts
Sensing
True RMS
Polarity
Automatic
Update rate
5 per second nominal
Operating
temperature
32
°
F to 104
°
F (0
°
C to 40
°
C)
Relative
humidity
Maximum relative humidity 80% for temperature up to
31
°
C, decreasing linearly to 50% relative humidity at 40
°
C
Storage
temperature
-4
°
F to 140
°
F (-20
°
C to 60
°
C), < 80% R.H. (with battery
removed)
Pollution
degree
2
Operating
altitude
≤
2000 m
Temperature
coefficient
nominal 0.15 x (specified accuracy)/
O
C @(0
O
C to 18
O
C or
28
O
C to 40
O
C), or otherwise specified
Transient
Protection
6.0 kV (1.2/50 μs surge)
Overload
protections
Current & Hz functions via jaws: 600 A ac/dc rms at
< 400Hz
Voltage & 3-Phase Rotation functions via terminals:
660 V dc / 920 V ac rms
Other functions via terminals: 600 V ac/dc rms
E.M.C.
Meets EN61326-1:2006
DC A and DC+AC A Functions, in an RF field of 1V/m:
Total Accuracy = Specified Ac 20 digits at around
405MHz
DC μA and Ohm Functions, in an RF field of 1V/m: Total
Accuracy = Specified Ac 25 digits
Other Functions, in an RF field of 3V/m: Total Accuracy =
Specified Ac 20 digits
Agency
approval
P
Power supply
Two 1.5V AAA Size battery
Power
consumption Typical 13mA for Current functions; 4.3mA for others
Low battery
indication
Approx. 2.85 V for Capacitance & Hz; approx. 2.5 V for
other functions
Auto power
off
Idle for 32 minutes
Auto power
off power
consumption
5μA typical
Summary of Contents for AMP-210