Amphenol RJS-5ES Series User Manual Download Page 8

Unmanaged Switch User Manual 

Page 8 of 13   

 

   Last Revised: 11-Jul-06 

Amphenol

 – 948, Promenade de l‘Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com

 

 

Pin 

 MDI-X 

Port 

MDI Port 

(typical for 

uplink) 

Auto-

MDI/ 

MDI-X 

Ethernet 

Device 

Port 

1 TX+ 

RX+  TX/RX+ RX+ 

2 TX- 

RX-  TX/RX-  RX- 

3 RX+ 

TX+  RX/TX+ TX+ 

Ethernet  
Connector  
Pin-outs

 

 

6 RX- 

TX-  RX/TX-  TX- 

 

 

 

 

The maximum cable length for 10/100BaseT(x) is typically 100 meters (328 ft.). 

 From 

To 

Maximum 

Distance 

 Switch 

Switch

 or Hub 

100 meters (328 feet) 

Cable Distance

 

 Switch

 or Hub 

PLC, Ethernet I/O, PC, etc. 

100 meters (328 feet) 

 

 

Note:

 Hubs and switches are different devices. Hubs simply broadcast all messages 

out all ports. switches intelligently route messages only out the appropriate port 

 

 

Ethernet 
Fiber Wiring 
Guidelines

 

These switches may have one or two pair of fiber ports of the type multimode or 
singlemode. Multimode ports support a maximum segment length of 2 km. Singlemode 
ports support a maximum segment length of 15 km, 40 km (long haul models) or even 
more (contact Amphenol.) 

Each fiber optic port on the switch is comprised of a pair of SC or ST connectors, which 
are labeled with “RX” and “TX” on the switch. When making your fiber optic 
connections, make sure that the transmit (TX) port of the switch connects to the receive 
(RX) port of the other device, and the receive (RX) port of the switch connects to the 
transmit (TX) port of the other device.  

The ACT/LNK LED will be ON solid when you have made a proper connection. 

 

 

 

Full or Half 
Duplex 
Operation

 

The RJ45 ports will auto-sense for Full or Half duplex operation. No user configuration 
is necessary. Each fiber optic port has a movable slide-switch or jumper that allows you 
to select the mode. The metal cover needs to be removed to access the movable jumper. 
See diagram below. 

Note: You must cycle power to the switch after changing the slide-
switch or jumper position. 

 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for RJS-5ES Series

Page 1: ...ing Page 6 Section 5 Ethernet Wiring Page 7 Section 6 Switching Features Page 9 Section 7 Technical Specifications Page 11 Section 8 Service Information Page 13 Applicable standards and certifications...

Page 2: ...d state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Amphenol disclaims any responsibility for damages either direc...

Page 3: ...Performance Specifications These general specifications apply to these switches Refer to Section 7 for complete technical specifications Ports models vary 10 100BaseT x Shielded RJ45 100BaseFX SC or...

Page 4: ...roper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 fo...

Page 5: ...iber 8 or 9 Copper Ports RJ45 0 275 0 70 cm 3 17 8 05 cm 2 935 7 45 cm ET GT 9ES Series Front View 4 75 12 07 cm 4 475 11 37 cm DIN EN 50022 not included 0 17 0 43 clear for 8 screw SC Fiber ST Fiber...

Page 6: ...to terminals 2 and 3 Optionally on the 5ES models a backup power supply may be connected Refer to the wiring diagram below Terminal 1 should be tied to panel or chassis ground P1 P2 VDC Supplies To P...

Page 7: ...for More Usage Ideas Note All 5 ports on the 5 port switch and ports 1 8 on the 9 port switch support auto speed duplex detection auto mdi mdix corssover and auto polarity Port 9 is an uplink port and...

Page 8: ...rts support a maximum segment length of 2 km Singlemode ports support a maximum segment length of 15 km 40 km long haul models or even more contact Amphenol Each fiber optic port on the switch is comp...

Page 9: ...t on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port...

Page 10: ...s defined by IEEE 802 3 will be dropped This includes short frames long frames CRC error frames and alignment error frames IEEE 802 3 compliant The Amphenol Industrial Ethernet Switch strictly abides...

Page 11: ...ed Max cable distance 100 meters Multimode Fiber Port 100BaseFX Fiber port mode Multimode Fiber port connector Duplex SC or ST Optimal fiber cable 50 125 62 5 125 m Center wavelength 1300 nm TX output...

Page 12: ...d full duplex Environmental Required supply voltage 10 30 VDC Power consumption typical Max 8 Watts Note Power consumption varies on speed and amount of activity of each port 5ES 1 4 0 Watts 5ES 2 3 5...

Page 13: ...ed under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on th...