Amphenol RJS-5ES Series User Manual Download Page 5

Unmanaged Switch User Manual 

Page 5 of 13   

 

   Last Revised: 11-Jul-06 

Amphenol

 – 948, Promenade de l‘Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com

 

 

Section 3 

Installation 

 

Overview 
 

All switches share the same footprint and can be snapped onto a standard DIN rail 
(EN50022) or screwed directly to a flat panel. Refer to the mechanical drawing below. 

Note:

 The Ethernet connections for the ET-5ES-1 come out the face of the unit. The 

Ethernet connections for all other models come out the top. Make sure to allow enough 
room to route your Ethernet cables. 

 

1.60"

[4.07 cm]

Power

0.235"

[0.60 cm]

0 or 1

Fiber Port

(SC or ST)

0.40"

[1.02 cm]
(max. for
ST Fiber)

8 or 9

Copper Ports

(RJ45)

0.275"

[0.70 cm]

3.17"

[8.05 cm]

2.935"

[7.45 cm]

ET-GT-9ES Series

Front View

4.75" [12.07 cm]

4.475" [11.37 cm]

DIN EN

50022

(not

included)

0.17"

[0.43]

(clear for

#8 screw)

SC Fiber

ST Fiber

 

1.38" [3.5 cm]

1.06" [2.7 cm]

0.30"

[0.76 cm]

DIN EN50022

(not included with units;

not shown to scale;

for reference only)

B

Side View

A

5 port model with no fiber:

A=1.20" [3.05 cm]; B=0.55" [1.40 cm]

 5 port model with single fiber:

A=1.20" [3.05 cm]; B=0" [0 cm]

5 port model with dual fiber: 

A=1.95" [4.95 cm]; B=0.35" [0.90 cm]

DIN EN50022

(not included with units;

not shown to scale;

for reference only)

0.30"

[0.76 cm]

1.06" [2.7 cm]

1.38" [3.5 cm]

A

B

Side View

Version 1.## units (prior to 11/04):

A=1.65" [4.19 cm]; B=0.85" [2.16 cm]

Version 2.## units (after 11/04): 

A=1.95" [4.95 cm]; B=0.35" [0.90 cm]

 

5 Port Model – Side View 

9 Port Model – Side View 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for RJS-5ES Series

Page 1: ...ing Page 6 Section 5 Ethernet Wiring Page 7 Section 6 Switching Features Page 9 Section 7 Technical Specifications Page 11 Section 8 Service Information Page 13 Applicable standards and certifications...

Page 2: ...d state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Amphenol disclaims any responsibility for damages either direc...

Page 3: ...Performance Specifications These general specifications apply to these switches Refer to Section 7 for complete technical specifications Ports models vary 10 100BaseT x Shielded RJ45 100BaseFX SC or...

Page 4: ...roper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 fo...

Page 5: ...iber 8 or 9 Copper Ports RJ45 0 275 0 70 cm 3 17 8 05 cm 2 935 7 45 cm ET GT 9ES Series Front View 4 75 12 07 cm 4 475 11 37 cm DIN EN 50022 not included 0 17 0 43 clear for 8 screw SC Fiber ST Fiber...

Page 6: ...to terminals 2 and 3 Optionally on the 5ES models a backup power supply may be connected Refer to the wiring diagram below Terminal 1 should be tied to panel or chassis ground P1 P2 VDC Supplies To P...

Page 7: ...for More Usage Ideas Note All 5 ports on the 5 port switch and ports 1 8 on the 9 port switch support auto speed duplex detection auto mdi mdix corssover and auto polarity Port 9 is an uplink port and...

Page 8: ...rts support a maximum segment length of 2 km Singlemode ports support a maximum segment length of 15 km 40 km long haul models or even more contact Amphenol Each fiber optic port on the switch is comp...

Page 9: ...t on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port...

Page 10: ...s defined by IEEE 802 3 will be dropped This includes short frames long frames CRC error frames and alignment error frames IEEE 802 3 compliant The Amphenol Industrial Ethernet Switch strictly abides...

Page 11: ...ed Max cable distance 100 meters Multimode Fiber Port 100BaseFX Fiber port mode Multimode Fiber port connector Duplex SC or ST Optimal fiber cable 50 125 62 5 125 m Center wavelength 1300 nm TX output...

Page 12: ...d full duplex Environmental Required supply voltage 10 30 VDC Power consumption typical Max 8 Watts Note Power consumption varies on speed and amount of activity of each port 5ES 1 4 0 Watts 5ES 2 3 5...

Page 13: ...ed under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on th...