Amphenol RJS-5ES Series User Manual Download Page 11

Unmanaged Switch User Manual 

Page 11 of 13  

 

   Last Revised: 11-Jul-06 

Amphenol

 – 948, Promenade de l‘Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 – www.rjswitch.com

 

 

Section 7 

Technical Specifications 

 

Technical 

Specifications 

Here are the technical specifications for these switches covered by this manual. 

 

 

Copper Ports: (10/100BaseTx) 

10/100BaseT(x) ports 

Shielded RJ45  

Protocols supported 

All standard IEEE 802.3 

Ethernet compliancy 

IEEE 802.3, 802.3u, 802.3x 

Auto-crossover  

Yes , Auto-mdi/mdix-crossover 

Auto-negotiating 

10BaseT or 100BaseTX 

Auto-polarity 

Yes (except port 9) 

Flow control 

Half or full duplex (port 9 is full duplex only) 

Ethernet isolation 

1500 VRMS 1 minute 

Plug and play 

Yes 

Cable requirements 

Twisted pair (Cat. 5 or better) (shielded recommended) 

Max. cable distance 

100 meters 

 

Multimode Fiber Port: (100BaseFX) 

Fiber port mode 

Multimode 

Fiber port connector 

Duplex SC or ST 

Optimal fiber cable 

50/125, 62.5/125 µm 

Center wavelength 

1300 nm 

TX output power 
RX input sensitivity 

Contact Amphenol for optical details. 

Maximum distance 

4 km (see web or details) 

Half and full duplex 

Switch or jumper selectable 

Ethernet compliance 

100BaseFX 

Eye safety 

IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11 

 

Singlemode Fiber Port: (100BaseFX) 

Fiber port mode 

Singlemode 

Fiber port connector 

Duplex SC or ST 

Optimal fiber cable 

9/125, 10/125 µm 

Center wavelength 

1300 nm 

TX output power 
RX input sensitivity 

Contact Amphenol for optical details. 

Maximum distance 

20 km, 40 km (long haul models) or more (contact Amphenol) 

Half and full duplex 

Switch or jumper selectable 

Ethernet compliance 

100BaseFX 

Eye safety 

IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11 

 

 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for RJS-5ES Series

Page 1: ...ing Page 6 Section 5 Ethernet Wiring Page 7 Section 6 Switching Features Page 9 Section 7 Technical Specifications Page 11 Section 8 Service Information Page 13 Applicable standards and certifications...

Page 2: ...d state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular Amphenol disclaims any responsibility for damages either direc...

Page 3: ...Performance Specifications These general specifications apply to these switches Refer to Section 7 for complete technical specifications Ports models vary 10 100BaseT x Shielded RJ45 100BaseFX SC or...

Page 4: ...roper Ethernet connection Link between the port and another Ethernet device Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends See section 5 fo...

Page 5: ...iber 8 or 9 Copper Ports RJ45 0 275 0 70 cm 3 17 8 05 cm 2 935 7 45 cm ET GT 9ES Series Front View 4 75 12 07 cm 4 475 11 37 cm DIN EN 50022 not included 0 17 0 43 clear for 8 screw SC Fiber ST Fiber...

Page 6: ...to terminals 2 and 3 Optionally on the 5ES models a backup power supply may be connected Refer to the wiring diagram below Terminal 1 should be tied to panel or chassis ground P1 P2 VDC Supplies To P...

Page 7: ...for More Usage Ideas Note All 5 ports on the 5 port switch and ports 1 8 on the 9 port switch support auto speed duplex detection auto mdi mdix corssover and auto polarity Port 9 is an uplink port and...

Page 8: ...rts support a maximum segment length of 2 km Singlemode ports support a maximum segment length of 15 km 40 km long haul models or even more contact Amphenol Each fiber optic port on the switch is comp...

Page 9: ...t on the switch used for a given MAC address is automatically learned when a frame is received from that address Once an address is learned the switch will route messages to only the appropriate port...

Page 10: ...s defined by IEEE 802 3 will be dropped This includes short frames long frames CRC error frames and alignment error frames IEEE 802 3 compliant The Amphenol Industrial Ethernet Switch strictly abides...

Page 11: ...ed Max cable distance 100 meters Multimode Fiber Port 100BaseFX Fiber port mode Multimode Fiber port connector Duplex SC or ST Optimal fiber cable 50 125 62 5 125 m Center wavelength 1300 nm TX output...

Page 12: ...d full duplex Environmental Required supply voltage 10 30 VDC Power consumption typical Max 8 Watts Note Power consumption varies on speed and amount of activity of each port 5ES 1 4 0 Watts 5ES 2 3 5...

Page 13: ...ed under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on th...