39
Part 1:
Package Contents
Receptacle connector
Notes: There will be no gasket when no sealing requirement.
Gasket
Dust Cap
Part 2:
Receptacle Assembly
Step 1:
Tighten M10x1.5 nut onto busbar (recommended torque is 13~14 Nm)
Busbar or other applications
Mount Panel
Spanner
M10 Spring
Washer
M10x1.5 Nut
a:
Receptacle tail (studs side) pass through the hole of mounting panel
b:
Studs pass through copper busbar and washer and nut in proper order
c:
Fix the power pin plane with a wrench
d:
Tighten nut by tool