INSTALLATION
Location:
The unit may be free standing or 19” rack mountable using the pair of rack
ears supplied. The screws which fix the rack ears to the unit are located at
the front of each side panel, as shown ( ) in the
Overview.
A PH2
screwdriver will be required to remove and replace the 2 pairs of screws
when fixing the rack ears in place. Remove four rubber feet.
The location must provide satisfactory ventilation for the equipment.
An internal fan provides forced ventilation using the air vents at the
left side (intake) and rear panel (exhaust) of the unit. Both of these vents
must be unobstructed for satisfactory cooling. If the unit is installed in an
enclosed environment, sufficient air flow into the enclosure must be
provided through vents, fans or other means, such that the units exhaust
air is not recycled to the inlet - causing it to OVERHEAT.
Slave
I/O
Output
Metal
Loss
Correction
Compression LEDs
Current LEDs
Overheat
LED
Microphone
Input
Microphone
Gain
Line
Gain
+15V
Loop
Current
Line
Input
Loop
Output
Loop
Monitor
Gain
Boost
Compressor
Phantom
Power
Switch
Overload
LED
Loop
Error
LED
Block Diagram
Connections
Connection of
male XLR for microphone
input
balanced
+ (Signal hot)
- (Signal cold)
1
2
3
Screen
TIP
SOURCE
TO ILD500
LINE INPUT
SLEEVE
RING
Connection of 3-pole Plug
with balanced signals.
Use Twin-screened cable.
+ (Signal hot)
- (Signal cold)
LINE
INPUT
MIC
INPUT
SLAVE
I/O
LOOP
CONNECTOR
+ (Signal)
TIP
SOURCE
TO ILD500
SLEEVE
RING
LINE INPUT
Connection of 3-pole plug.
Use Twin-screened cable.
Must be 3m or less.
Unbalanced
Balanced
TIP
RECORDING DEVICE
TO ILD500
SLAVE I/O
SLEEVE
RING
Connection of 3-pole Plug
to use Slave I/O socket
for recording output.
+ (Signal)
+15V
Power
Supply
Power
LED
Earth
Link
230V
or
120V
AC Power
-15V
0V
Power
Switch
15V
150mA
DC
Output
Socket
0V
+15V
-15V
Use cable supplied.
Must be 3m or less.
8.00mm
20.00mm
use either NL4 connections 1or 2, or both as required
1+
2+
LOOP +
1-
2-
LOOP -
Internal unit connections