INSTALLATION

Tools

You will require the following:

·

 

Small flat bladed screwdriver

·

 

Screws, fixings and appropriate tools for mounting CLD1-AC on wall etc.

Location

The amplifier should be mounted where:

·

 

It is in close proximity to the loop.

·

 

it is protected from drips or sprays of water.

·

 

it is not vulnerable to mechanical damage.

·

 

the controls can be accessed during set-up.

·

 

the cables will not be inadvertently caught or pulled out from the unit.

·

 

any heat generated during normal operation can escape.

The induction loop itself is a critical to correct system performance, either:

·

 

Unfold the loop coil and fit vertically inside the front panel of the counter 

using the adhesive fixings provided. The top of the loop coil should ideally 
be at a height of 800mm above the floor. See diagram in Quick start.

2

2

·

To cover a larger area, a perimeter loop using 0.5mm  to 1.5mm  cross-

section wire or equivalent. Return the feed to the amplifier with a 
twisted pair. Refer to 'Designing Induction Loops handbook' for details.

Please consult Ampetronic if you need more advice about the loop design.

Connections

LOOP: Connect the loop cable to the 'LOOP OUTPUT' socket.

1. To open the spring clamp terminal - insert a flat bladed screwdriver into the 

small “tab” above the hole. Push gently until hole opens.

2  Insert the wire (remove 7mm of insulation from end).
3. Remove the screwdriver - clamping the wire in place.

INPUTS: Both inputs are 3.5mm two pole (mono) jack sockets. They will not 

interface directly to any stereo signal source. Connect inputs as shown in the 
connection details. 

INPUT 1  Unbalanced electret microphone only.

INPUT 2  Microphone as INPUT 1, or Line level input. 

Note: Set the 'INPUT 2 

SELECT' switch to the appropriate position for the type of signal source used.

AC POWER: The 'POWER INPUT' socket accepts 100-240V . Connect to a 

AC

convenient AC power socket.

Summary of Contents for CLD1-AC

Page 1: ...ct ventilation of this unit Install in accordance with the manufacturer s instructions 5 Do not install near any heat sources such as radiators heating vents or other apparatus that produces heat 6 Re...

Page 2: ...de j Microphone input for use with unbalanced electret microphones k Selectable microphone or unbalanced line level input Mic mode as above l AC power input standard 2 pin AC power socket m Loop outpu...

Page 3: ...Connect the loop wires to LOOP OUTPUT terminals Polarity is not important To open the spring clamp terminal insert a flat bladed screwdriver into the small tab above the hole Push gently until hole o...

Page 4: ...LOCK DIAGRAM Balanced Input A B Screen Connect screen and ve signal lead together Stereo Source Left Right Screen Keep all wires very short 10k 10k L R Screen Ideally fit the two 10k W summing resisto...

Page 5: ...area a perimeter loop using 0 5mm to 1 5mm cross section wire or equivalent Return the feed to the amplifier with a twisted pair Refer to Designing Induction Loops handbook for details Please consult...

Page 6: ...iate see OPERATION Input signal level too low Check that signal level is the correct level for the chosen input see TECHNICAL SPECIFICATIONS LOOP CURRENT LED not illuminated even at peaks of signal Lo...

Page 7: ...e selectable with switch Fully anticlockwise flat response Mic mode same as Input 1 Environmental Line mode Ambient temperature 20 C to 50 C Input Impedance 820kW IP rating IP20 Sensitivity 20dBu 77 5...

Page 8: ...he product Description Induction Loop Driver Type name CLD1 AC conforms to the following directive s and Norm s 2014 35 EU The Low Voltage Directive LVD and its amending directives 2014 30 EU The Elec...

Reviews: